Analysis of some measurement issues in bushing power factor tests in the field

@article{Zhang2006AnalysisOS,
  title={Analysis of some measurement issues in bushing power factor tests in the field},
  author={S. Zhang},
  journal={IEEE Transactions on Power Delivery},
  year={2006},
  volume={21},
  pages={1350-1356}
}
  • S. Zhang
  • Published 26 June 2006
  • Physics
  • IEEE Transactions on Power Delivery
The power factor measurement is widely used in the evaluation of bushing insulation conditions in the field. Some measurement issues occur in the field tests which give abnormal readings of bushing C/sub 1/ and/or C/sub 2/ power factors. This paper provides an engineering analysis of the possible measurement issues in the bushing field tests such as testing a bushing on a transformer or in its shipping crate, or a bushing with wet/contaminated voltage/test tap or wet/dirty porcelain surface. 
Optimization of Electric Field in 230kV Power Transformers Bushing
Condenser bushings are one of the key components in power transformers. Although their price is negligible compared to the total price of the transformer their quality has an important effect on
Simulation for Transient Moisture Distribution and Effects on the Electric Field in Stable Condition: 110 kV Oil-Immersed Insulation Paper Bushing
TLDR
The OIP bushing was assumed to be in a stable and simplicity condition, and then the transient moisture distribution of capacitor core and its effects on the electric field were studied.
A Review on Traditional Methods of Condition Monitoring of Transformer
TLDR
Comparison of all the traditional condition monitoring techniques alongside with their respective reason, interpretation and limitation is done to help to understand better about the traditional techniques.
Overview and Partial Discharge Analysis of Power Transformers: A Literature Review
TLDR
The current state-of-the-art methods for PD detection and localization techniques, and methodologies in power transformers are reviewed and evaluated.
A Diagnostic Method for Moisture Intrusion Fault in OIP Bushing
TLDR
The results show that the proposed method can effectively diagnose the MIP of OIP bushings by the hidden Markov model (HMM) and the shuffled frog-leaping algorithm (SFLA).
Transformer Design and Optimization: A Literature Survey
With the fast-paced changing technologies in the power industry, new references addressing new technologies are coming to the market. Based on this fact, there is an urgent need to keep track of
Prioritizing Energy-Intensive Machining Operations and Gauging the Influence of Electric Parameters: An Industrial Case Study
TLDR
A hybrid decision-making technique based on TOPSIS and DoM was utilized to determine energy-intensive machining operation and the significance of electric parameters as predictors in power estimation of machining operations was highlighted.
Improved Power Factor of Electrical Generation by using Clustering Neural Network
  • A. Abed
  • Engineering, Computer Science
  • 2018
TLDR
This presented method of enhancing power factor of electrical generation system by mechanically controlling a power system is based on an clustering neural network, and the CNN achieves sufficiently both quick and sluggish varying load.
An Investigation of the Interaction Between Graphene and Hydrated Ions
The ability of graphene and carbon nanotubes to generate an electric potential from flowing fluids has attracted much interest [1–7]. The effect is thought to occur because certain ionic and
...
1
2
...

References

SHOWING 1-2 OF 2 REFERENCES
An improved method of measuring C/sub 1/ power factor of resistance-graded bushings
Summary form only given as follow. This paper discusses C/sub 1/ power factor of a condenser bushing with resistance graded (RG) porcelain and proposes a method to obtain the intrinsic power factor
Review negative power factor test results and case studies—Analysis and interpretation,
  • Int. Conf. Doble Clients,