Corpus ID: 27497909

Analysis of Indoor Air Quality and Development of New Air Cleaner for Railroad Passenger Cabin

@inproceedings{Park2008AnalysisOI,
  title={Analysis of Indoor Air Quality and Development of New Air Cleaner for Railroad Passenger Cabin},
  author={Duckshin Park and Soon-Bark Kwon and Youngmin Cho and Eunyoung Park and Seyoung Kim and M Jung},
  year={2008}
}
1 Citations

Figures and Tables from this paper

The analysis of indoor air quality inside the Kelana Jayalight rail transit train in Kuala Lumpur
In the name of Allah most gracious the most merciful. First and foremost, I would like to convey my deepest appreciation to my supervisor Associate Prof. Dr. Mutalib bin Leman for his openness toExpand

References

SHOWING 1-10 OF 11 REFERENCES
Classification of particulates in the air with use of cluster analysis and disjoint
  • 1996
Novel air distribution systems for commercial aircraft cabins
Air distribution systems in commercial aircraft cabins are important for providing a healthy and comfortable environment for passengers and crew. The mixing air distribution systems used in existingExpand
Effect of door opening on the performance of displacement ventilation in a typical office building
TLDR
It was found that the presence of large heat sources such as from a window can cause the lateral movement of airflow, disrupting the convection effect which the displacement ventilation system relies on. Expand
CFD analysis of ventilation effectiveness in a public transport interchange
A study was conducted into the ventilation effectiveness of a ventilation system within a public transport interchange (PTI) in Hong Kong. A computational fluid dynamics (CFD), steady stateExpand
Thermal comfort and indoor air quality in the lecture room
  • 2005
Regulatory standards related to building energy conservation and indoor-air-quality during rapid urbanization in China
Abstract The number of airtight buildings equipped with air-conditioning units along with levels of energy consumption from residential and commercial buildings has both increased markedly in ChinaExpand
Simulation of wind driven ventilative cooling systems for an apartment building in Beijing and Shanghai
Abstract This paper presents a performance evaluation of two passive cooling strategies, daytime ventilation and night cooling, for a generic, six-story suburban apartment building in Beijing andExpand
Classification of particulates in the air with use of cluster analysis and disjoint principal component analysis , Maste ' s thesis of Graduate School of Kyunghee University
  • 1996
Cluster analysis: A technique for estimating the synoptic meteorological controls on air and precipitation chemistry—Method and applications
Abstract Combining the pattern recognition capabilities of cluster analysis with isobaric air trajectory data is a useful way of quantifying the influence of synoptic meteorology on the pollutionExpand
Study on the analysis of air pollutant levels
  • 1990
...
1
2
...