Anaerobic treatment of sulfate-containing municipal wastewater with a fluidized bed reactor at 20 °C.

Abstract

This study focuses on the anaerobic treatment of sulfate-containing municipal wastewater at 20 °C with a fluidized bed reactor. Mean influent chemical oxygen demand (COD) and sulfate concentrations were 481 and 96 mg/l. The response of the COD removal efficiency to increasing organic loading rates (OLR) was investigated. Average total COD removal was 61% at… (More)
DOI: 10.2166/wst.2016.109

Topics

Cite this paper

@article{Dppenbecker2016AnaerobicTO, title={Anaerobic treatment of sulfate-containing municipal wastewater with a fluidized bed reactor at 20 °C.}, author={B. D{\"u}ppenbecker and Peter Cornel}, journal={Water science and technology : a journal of the International Association on Water Pollution Research}, year={2016}, volume={73 10}, pages={2446-52} }