An active damping technique for multiple grid-connected converters

@article{Chen2017AnAD,
  title={An active damping technique for multiple grid-connected converters},
  author={Hsin-Chih Chen and Po-Tai Cheng},
  journal={2017 IEEE 3rd International Future Energy Electronics Conference and ECCE Asia (IFEEC 2017 - ECCE Asia)},
  year={2017},
  pages={561-566}
}
The LCL-filter is one of the methods to reduce the size of the filter inductor but it leads to resonance in the system. The resonance usually results in unstable system and triggers the over-current protection. An active damping technique based on the virtual resistor is provided in this paper. The concept and the mathematical analysis of the proposed method are explained, and then the stability of the single converter operation and multiple grid-connected converter operation are analysed… CONTINUE READING

Citations

Publications citing this paper.

Observer-based active damping for grid-connected converters with LCL filter

2018 International Power Electronics Conference (IPEC-Niigata 2018 -ECCE Asia) • 2018
View 3 Excerpts
Highly Influenced

References

Publications referenced by this paper.
Showing 1-10 of 15 references

Analysis of the passive damping losses in lcl-filter-based grid converters

R. Pena-Alzola, M. Liserre, +3 authors F. W. Fuchs
IEEE Transactions on Power Electronics, vol. 28, no. 6, pp. 2642–2646, 2013. • 2013
View 1 Excerpt

Generalized Design of High Performance Shunt Active Power Filter With Output LCL Filter

IEEE Transactions on Industrial Electronics • 2012
View 2 Excerpts

On the stability of discrete-time active damping methods for VSI converters with a LCL input filter

IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society • 2012
View 1 Excerpt

Similar Papers

Loading similar papers…