An Integrated Sideband-Separating SIS Mixer Based on Waveguide Split Block for 100 GHz Band with 4.0–8.0 GHz IF

@article{Asayama2004AnIS,
  title={An Integrated Sideband-Separating SIS Mixer Based on Waveguide Split Block for 100 GHz Band with 4.0–8.0 GHz IF},
  author={Shinichiro Asayama and H. Ogawa and T. Noguchi and K. Suzuki and H. Andoh and A. Mizuno},
  journal={International Journal of Infrared and Millimeter Waves},
  year={2004},
  volume={25},
  pages={107-117}
}
We have developed an integrated sideband-separating SIS mixer for the 100 GHz band based on the waveguide split block. The measured receiver noise temperatures with 4.0–8.0 GHz IF are less than 60 K in the LO frequency range of 90–110 GHz, and a minimum value of around 45 K is achieved at 100 GHz. The image rejection ratios are more than 10 dB in the frequency range of 90–110 GHz. We have installed the sideband-separating SIS mixer into an atmospheric ozone-measuring system at Osaka Prefecture… Expand