• Corpus ID: 32687340

An Estimation Technique using FFT for Heart Rate Derived from PPG Signal

@article{BM2015AnET,
  title={An Estimation Technique using FFT for Heart Rate Derived from PPG Signal},
  author={Jayadevappa B.M and Mallikarjun S. Holi},
  journal={Global Journal of Research In Engineering},
  year={2015},
  volume={15}
}
Heart rate (HR) observation by using photoplethysmography (PPG) signals during intense physical activity is a crucial task because of the fact that PPG signals are affected by the noise due to movement artifacts by the user's hand movements. This paper addresses the discriminating assessment of a novel encapsulation for wearable PPG sensor during the severe physical activity. In this work, we plan the HR estimation issue, and utilization of proposed algorithm to find high-determination power… 

Figures from this paper

Performance Comparison of Variants of LMS Algorithms for Motion Artifact Removal in PPG Signals During Physical Activities
TLDR
The results show that the general L MS algorithm and the normalized LMS algorithm perform better than the other variants of LMS algorithms and that thegeneral LMSgorithm performs betterthan the SVD.
Portable health monitoring kit using photolethysmogram signal
TLDR
PPG signal has the capability to monitor the health status of an individual, which acts as an alternative biological signal for the existing health monitoring systems.
Blood Pressure Estimation from Photoplethysmography with Motion Artifacts Using Long Short Term Memory Network
TLDR
Long Short Term Memory (LSTM) an extension of RecurrentNeural Networks (RNN) is used used to improve the accuracy of the estimation of the BP from the corrupted PPG.
Self-Adaptive Matrix Completion for Heart Rate Estimation from Face Videos under Realistic Conditions
TLDR
This work introduces a strategy to dynamically select face regions useful for robust HR estimation, inspired by recent advances on matrix completion theory, which significantly outperforms state-of-the-art HR estimation methods in naturalistic conditions.
Research on Collaborative Physiological Health Monitoring and Sharing Technology in Mobile Application
TLDR
This paper studies non-contact heart rate monitoring technology based on visible light and constructs the physiological signs network for group users and achieves natural and convenient physiological health monitoring and community health information sharing for network relationship support.

References

SHOWING 1-10 OF 12 REFERENCES
A Robust Algorithm for Derivation of Heart Rate Variability Spectra from ECG and PPG Signals
TLDR
A robust algorithm was developed to derive HRV signals, their FFT- or AR-based spectra and their standard spectral features from either electrocardiogram (ECG) or photoplethysmographic (PPG) signals to quantify parasympathetic influences and sympathovagal balance.
Investigation of effects of time domain features of the photoplethysmography (PPG) signal on sleep respiratory arrests
TLDR
Photoplethysmography could be used more efficiently using a computer software in the scoring of respiratory events, and there are not significant differences between apnea and hypopnea classes.
Use of Fourier Series Analysis for Motion Artifact Reduction and Data Compression of Photoplethysmographic Signals
TLDR
Experimental results indicate that the proposed method is insensitive to heart rate variation, introduces negligible error in the processed PPG signals due to the additional processing, preserves all the morphological features of the PPG, provides 35 dB reduction in motion artifacts, and achieves a data compression factor of 12.
A Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter
TLDR
The merit of the method is clearly demonstrated using convergence and correlation analysis, thus making it best suitable for present-day pulse oximeters utilizing PPG sensor head with a single pair of source and detector, which does not have any extra hardware meant for capturing noise reference signal.
On the performance of Time Varying Step-size Least Mean Squares(TVS-LMS) adaptive filter for MA reduction from PPG signals
TLDR
An efficient adaptive filtering technique based on Time Varying Step-size Least Mean Squares (TVS-LMS) algorithm for MA reduction, where a synthetic noise reference signal for adaptive filtering, representing MA noise, is generated internally from the MA corrupted PPG signal itself instead of using any additional hardware such as accelerometer or source-detector pair.
Continuous blood pressure measurement algorithm based on PPG signal quality assessment
  • Xu Lin, Gao Kunpeng
  • Computer Science
    The 27th Chinese Control and Decision Conference (2015 CCDC)
  • 2015
TLDR
A pulse waveform quality evaluation function to calculate the pulse wave quality index that has the least extreme errors and the smallest root mean square error (rMSE) of systolic blood pressure (SBP).
Wearable Photoplethysmographic Sensors—Past and Present
Photoplethysmography (PPG) technology has been used to develop small, wearable, pulse rate sensors. These devices, consisting of infrared light-emitting diodes (LEDs) and photodetectors, offer a
Estimating heart rate using wrist-type Photoplethysmography and acceleration sensor while running
TLDR
The heart rate estimation method reported has a higher degree of usability compared to existing methods using ECG and is closer to the holter Electrocardiogram (ECG) in high accuracy.
An effective three way PPG acquiring and signal processing system by using square wave modulation
TLDR
The proposed PPG acquiring and signal processing system is able to acquire stable PPG signals to accurately derive the physiological indexes of cardiovascular system such as heart rate, respiratory rate, oxygen concentration, etc.
A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic Biosensors
TLDR
A novel real-time adaptive algorithm is proposed for accurate motion-tolerant extraction of heart rate and pulse oximeter oxygen saturation from wearable photoplethysmographic (PPG) biosensors and provides noise-free PPG waveforms for further feature extraction.
...
...