Ambulatory Impedance Cardiography: A Systematic Review

@article{Parry2006AmbulatoryIC,
  title={Ambulatory Impedance Cardiography: A Systematic Review},
  author={Monica Parry and Judith A McFetridge-Durdle},
  journal={Nursing Research},
  year={2006},
  volume={55},
  pages={283-291}
}
Background: Standard noninvasive impedance cardiography has been used to examine the cardiovascular responses of individuals to a wide range of stimuli in critical care and laboratory settings. It has been shown to be a reliable alternative to invasive thermodilution techniques and an acceptable alternative to the use of a pulmonary artery catheter. Ambulatory impedance cardiography provides a similar assessment of cardiac function to standard noninvasive impedance cardiography, but it does so… Expand
Value of Impedance Cardiography in Patients Studied for Pulmonary Hypertension
TLDR
In patients withPH, impedance cardiography had good accuracy and fair precision for CO determination when compared with thermodilution, and has the potential to become a cost-effective and noninvasive method for the follow-up of patients with PH. Expand
Ambulatory Impedance Cardiography in Hypertension: A Validation Study
TLDR
The sensitivity of the AIM to detect hemodynamic changes associated with postural shift in persons with hypertension is evaluated and it is demonstrated that the A IM provides valid and reliable estimates of cardiac function in people with hypertension. Expand
Ambulatory Impedance Cardiography
In this chapter the idea of the impedance cardiography will be presented followed by a description of a central hemodynamics ambulatory monitoring system, available for both research and clinicalExpand
A Novel Noninvasive Device to Assess Sympathetic Nervous System Function in Patients With Heart Failure
TLDR
Although the VU-AMS version 5fs system detected anticipated hemodynamic and sympathetic nervous system changes to postural shift in participants, the elimination of 64% of the sample because of scoring difficulties limits the use of this impedance cardiography device using standard scoring algorithms in persons with heart failure with reduced ejection fraction. Expand
Noninvasive investigation of the cardiodynamic response to 6MWT in people after stroke using impedance cardiography
  • Fang Liu, Alice Y M Jones, +4 authors Yulong Wang
  • Medicine
  • PloS one
  • 2020
TLDR
Sub-group analysis showed that the increase in cardiac output was predominantly contributed by an increase in heart rate in participants diagnosed with stroke for less than 1 year, whereas both stroke volume and heart rate contributed similarly to the increaseIn cardiac output in participants with diagnosis of stroke for longer than 1year. Expand
Intrarater reliability and agreement of the physioflow bioimpendance cardiography device during rest, moderate and High-intensity exercise
TLDR
Heart rate, stroke volume, cardiac output, left cardiac work index and end diastolic volume demonstrated a good level of reliability at rest, during submaximal exercise and high-intensity interval exercise, and all other variables demonstrated inconsistent reliability across activity types and intensities. Expand
Hemodynamic Response to Postural Shift in Women with Multiple Chemical Sensitivities
TLDR
The hemodynamic response to postural shift in 17 women with MCS was normal, and the magnitude of the changes was considerably less than those observed previously in healthy participants. Expand
Rheocardiography, an advanced noninvasive circulatory system test in children and adults: Progress and prospects
TLDR
An overview of theoretical studies and clinical practice of using thoracic electrical bioimpedance, a noninvasive method for the measurement of cardiac output, cardiac index, systolic time intervals, and other hemodynamic parameters, is provided. Expand
The economic evaluations of interventions for heart diseases
TLDR
Fundamental issues in parametric distribution functions and Markov modelling approaches have been revisited, with detailed consideration of which parametric Distribution functions should be employed when extrapolating beyond a trial and how they could be adopted into model-based analyses. Expand
Continuous non-invasive blood pressure estimation
TLDR
The goal of this thesis is to investigate novel non‐invasive technologies for the continuous measurement of BP, with particular emphasis on non‐occlusive technologies that can be used in ambulatory scenarios, during daily life activities and not only within hospitals or physicians' offices. Expand
...
1
2
3
...

References

SHOWING 1-10 OF 52 REFERENCES
Ambulatory impedance cardiography: a feasibility study.
TLDR
Cardiac responses to postural shift, expressed as change measures from sitting to standing, were also comparable for the AIM and Minnesota reference monitoring systems. Expand
New ambulatory impedance cardiograph validated against the Minnesota Impedance Cardiograph.
TLDR
The validity and reliability of a new ambulatory impedance cardiograph was tested against the Minnesota Impedance Cardiograph during rest, orthostasis, and mental stress and appears to provide valid and reliable estimates of cardiac function at rest and during behavioral challenges in the lab. Expand
Methodological guidelines for impedance cardiography.
TLDR
The various aspects of impedance methodology are discussed, and alternative approaches described, with the objective of providing an informed basis for choosing among these methodological alternatives. Expand
Impedance cardiography: the next vital sign technology?
TLDR
The latest ICG technology for determining CO (CO-ICG) is less variable and more reproducible in an intrapatient sense than is CO-TD, it is equivalent to the average acceptedCO-TD in post-coronary artery bypass graft patients, and showed marked improvement in agreement with CO- TD compared to measurements made using previous generation ICG CO equations. Expand
Noninvasive physiologic monitoring of high-risk surgical patients.
TLDR
The multicomponent noninvasive monitoring provides continuous online, real-time displays of physiologic data that allow immediate recognition of circulatory dysfunction as well as the means to titrate therapy to appropriate predetermined therapeutic goals. Expand
Large-scale ensemble averaging of ambulatory impedance cardiograms
  • H. Riese, P. Groot, +6 authors E. J. Geus
  • Psychology, Medicine
  • Behavior research methods, instruments, & computers : a journal of the Psychonomic Society, Inc
  • 2003
TLDR
Results indicate that for unambiguous ambulatory impedance cardiograms, large-scale ensemble averaging is valid, which makes measuring prolonged changes in cardiac sympathetic activity by measuring ambulatory PEP feasible even in large epidemiological samples. Expand
Is noninvasive hemodynamic monitoring appropriate for the elderly critically injured patient?
TLDR
Noninvasive cardiac index monitoring in elderly patients is reliable and correlates well with standard thermodilution techniques, according to the purpose of the present study. Expand
Noninvasive ambulatory assessment of cardiac function in healthy men exposed to carbon monoxide during upper and lower body exercise
TLDR
It is concluded that young, apparently healthy men can perform submaximal upper and lower-body exercise without overt impairment of cardiovascular function after CO exposures attaining 20% COHb. Expand
Outpatient cardiovascular management utilizing impedance cardiography.
TLDR
Elect impedance cardiography technology and the use of impedanceCardiography in the home and outpatient clinic settings for the assessment and management of heart failure, resistant hypertension, and dual-chamber pacemaker optimization are reviewed. Expand
Multicenter study of noninvasive monitoring systems as alternatives to invasive monitoring of acutely ill emergency patients.
TLDR
Noninvasive monitoring systems gave continuous displays of physiologic data that provided information allowing early recognition of low flow and poor tissue perfusion that were more pronounced in the nonsurvivors, and may be acceptable alternatives where invasive monitoring is not available. Expand
...
1
2
3
4
5
...