Ambient neutron dose equivalent outside concrete vault rooms for 15 and 18 MV radiotherapy accelerators.

Abstract

In this work, the ambient dose equivalent, H*(10), due to neutrons outside three bunkers that house a 15- and a 18-MV Varian Clinac 2100C/D and a 15-MV Elekta Inor clinical linacs, has been calculated. The Monte Carlo code MCNPX (v. 2.5) has been used to simulate the neutron production and transport. The complete geometries including linacs and full… (More)
DOI: 10.1093/rpd/ncr208