Abrasion resistance of two types of nonabsorbable braided suture.

@article{Lo2004AbrasionRO,
  title={Abrasion resistance of two types of nonabsorbable braided suture.},
  author={Ian K Y Lo and Stephen S. Burkhart and Kyriacos Athanasiou},
  journal={Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association},
  year={2004},
  volume={20 4},
  pages={407-13}
}
PURPOSE The purpose of this study was to compare the abrasion resistance of different types of non-absorbable braided sutures under varying in vitro conditions of cyclic loading. TYPE OF STUDY Biomechanical study. METHODS Two types of nonabsorbable braided sutures were used in this study, No. 2 Ethibond and No. 2 Fiberwire, combined with 5 different anchors: 5.0-mm Corkscrew anchor, 5.0-mm BioCorkscrew anchor, 3.0-mm BioFastak anchor, Panalok RC anchor, and 3.5-mm Panalok anchor. Twelve… CONTINUE READING