A rapid method for the separation of vitamin D and its metabolites by ultra-high performance supercritical fluid chromatography-mass spectrometry.

@article{Jumaah2016ARM,
  title={A rapid method for the separation of vitamin D and its metabolites by ultra-high performance supercritical fluid chromatography-mass spectrometry.},
  author={Firas Jumaah and Sara Larsson and S. Ess{\'e}n and L. Cunico and C. Holm and C. Turner and M. Sandahl},
  journal={Journal of chromatography. A},
  year={2016},
  volume={1440},
  pages={
          191-200
        }
}
In this study, a new supercritical fluid chromatography-mass spectrometry (SFC-MS) method has been developed for the separation of nine vitamin D metabolites within less than eight minutes. This is the first study of analysis of vitamin D and its metabolites carried out by SFC-MS. Six columns of orthogonal selectivity were examined, and the best separation was obtained by using a 1-aminoanthracene (1-AA) column. The number and the position of hydroxyl groups in the structure of the studied… Expand
A fast and sensitive method for the separation of carotenoids using ultra-high performance supercritical fluid chromatography-mass spectrometry
AbstractIn this study, a rapid and sensitive ultra-high performance supercritical fluid chromatography-mass spectrometry (UHPSFC-MS) method has been developed and partially validated for theExpand
Quantitative analysis of vitamin D and its main metabolites in human milk by supercritical fluid chromatography coupled to tandem mass spectrometry
TLDR
The newly developed method provides opportunities to determine the nutritional status of mother-infant dyads from a non-invasive measure, or for interventional or observational studies building knowledge on the composition of human milk. Expand
Simultaneous determination of Vitamin A, 25-hydroxyl vitamin D3 α-tocopherol in small biological fluids by liquid chromatography-tandem mass spectrometry.
  • Haifeng Zhang, Li Quan, +7 authors J. Huo
  • Chemistry, Medicine
  • Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
  • 2018
TLDR
A sensitive method for the simultaneous analysis of vitamin A, 25-hydroxyl vitamin D3 and α-tocopherol in children plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed and validated and suitable for children, especially infants and newborns' sample detection, in whom the circulation blood was low. Expand
Routine Supercritical Fluid Chromatography Tandem Mass Spectrometry Method for Determination of Vitamin K1 Extracted from Serum with a 96-Well Solid-Phase Extraction Method.
TLDR
The method allows high-throughput reliable determination of vitamin K1 in serum in the range 0.1-50 ng/mL with a correlation coefficient of R2 >0.999 and is currently in routine use for analysis of serum samples. Expand
Determination of vitamin D3 in daily oily supplements by a two-dimensional supercritical fluid chromatography-liquid chromatography-mass spectrometry system.
TLDR
The results indicate that the two-dimensional SFC-MS/SFC-LC-MS system is useful for determination of vitamin D in oily drops and if it works at S FC-MS mode, the internal standard is required. Expand
Determination of vitamin D in oily drops using a column-switching system with an on-line clean-up by supercritical fluid chromatography.
TLDR
The results suggest that the method based on the SFC-RPLC/MS column-switching system is simple and suitable for analysis of vitamin D in oily and fatty samples. Expand
Enantioselective supercritical fluid chromatography-tandem mass spectrometry method for simultaneous estimation of risperidone and its 9-hydroxyl metabolites in rat plasma.
TLDR
The method was validated and was successfully applied for simultaneous estimation of RIS and 9-hydroxyrisperidone metabolites (R & S individually) after intravenous and per oral administration to rats. Expand
Simultaneous profiling of vitamin D metabolites in serum by supercritical fluid chromatography-tandem mass spectrometry (SFC-MS/MS).
TLDR
The developed and validated a SFC-MS/MS method, which is capable of eluting hydrophobic molecules, is appropriate for high throughput analysis of multiple VD metabolites in human serum with reduced solvent and economic cost. Expand
Determination of Five Retinol Isomers in Animal Livers Using Ultra-High Performance Supercritical Fluid Chromatography
A novel and efficient ultra-high performance supercritical fluid chromatography method was developed for the quantitative analysis of five retinol isomers in animal livers. The separation of the fiveExpand
Optimization and validation of a fast supercritical fluid chromatography method for the quantitative determination of vitamin D3 and its related impurities.
TLDR
The validity of an SFC method for the QC of vitamin D3 raw material and its application to real samples supports the switch to a greener and faster separative technique as an alternative to NPLC in the pharmaceutical industry. Expand
...
1
2
3
4
5
...

References

SHOWING 1-10 OF 32 REFERENCES
Comparison of analysis of vitamin D3 in foods using ultraviolet and mass spectrometric detection.
  • W. Byrdwell
  • Chemistry, Medicine
  • Journal of agricultural and food chemistry
  • 2009
A method for analysis of vitamin D(3) in commonly fortified foods and in fish, which contains endogenous vitamin D(3), was developed by combining the best aspects of two official methods. The ethylExpand
Determination of cholecalciferol (vitamin D3) in selected foods by liquid chromatography: NMKL collaborative study.
Results are presented from an NMKL (Nordic Committee on Food Analysis) collaborative study of a method for the determination of cholecalciferol (vitamin D3) in foods. The method is based on theExpand
Progress of liquid chromatography-mass spectrometry in measurement of vitamin D metabolites and analogues.
TLDR
LC-MS has unique advantages in measuring various vitamin D metabolites and analogues due to its flexibility, sensitivity, and specificity and will be used for standardizing serum 25(OH)D assays using reference materials available from the National Institute of Standards and Technology. Expand
Quantitative determination of vitamin D metabolites in plasma using UHPLC-MS/MS
TLDR
An assay using ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) was established to allow for the simultaneous determination of five vitamin D metabolites in low volumes of human plasma, demonstrating the high degree of comparability of the new UHPLC/MS technique to existing methods. Expand
Method developments approaches in supercritical fluid chromatography applied to the analysis of cosmetics.
TLDR
Simple method development guidelines in SFC are described, involving UV-filters in sunscreen cream, glyceryl caprylate in eye liner and caffeine in eye serum, and the importance of the detector type, UV or ELSD, and of the particle size of the stationary phase is discussed. Expand
Quantitative analytical method to evaluate the metabolism of vitamin D.
TLDR
The analytical features of the method support its applicability in nutritional and clinical studies targeted at elucidating the role of vitamin D metabolism, and externally validated according to the vitamin D External Quality Assurance Scheme through the analysis of ten serum samples provided by this organism. Expand
Comparison of ultra-high performance supercritical fluid chromatography and ultra-high performance liquid chromatography for the analysis of pharmaceutical compounds.
TLDR
By combining the use of small particles with supercritical fluids as a mobile phase, it was possible to achieve the analysis of pharmaceutical compounds in less than 1 min or to attain a peak capacity of more than 250 in approximately 40 min, both with a high degree of repeatability. Expand
Determination of vitamin D3 in cod-liver oil (Lebertran) by high-pressure liquid chromatography
ZusammenfassungEin Verfahren zur HPLC-Bestimmung von Vitamin D3 in Lebertran mit Hilfe einer Partisil-10 pxs-Säule (Whatman) mit der mobilen Phase Chloroform-n-Hexan-Eisessig (70∶30∶1) undExpand
Analysis of vitamin D metabolic markers by mass spectrometry: current techniques, limitations of the "gold standard" method, and anticipated future directions.
TLDR
The present review will highlight detrimental influences of the biological matrix, epimer contributions, pitfalls of specific mass spectrometry data acquisition routines (in particular multiple reaction monitoring, MRM), influence of ionization source, derivatization reactions, inter-laboratory comparisons on precision, accuracy, and application range of vitamin D metabolites. Expand
Analytical methods and performance of the immunoassay methods for determination of vitamin d in comparison to mass spectrometry / Analitičke metode i izvođenje imunometrijskih određivanja vitamina d u poređenju sa masenom spektrometrijom
TLDR
Most immunoassays available today are acceptable for clinical use and might be method of choice for smaller laboratories, but larger clinical laboratories and institutions that possess technical expertise, particularly the ones with large pediatric population where assay sensitivity and specificity may be important, might find LC-MS/MS methodology a more suitable choice. Expand
...
1