A rapid, specific membrane filtration procedure for enumeration of enterococci in recreational water.

@article{Messer1998ARS,
  title={A rapid, specific membrane filtration procedure for enumeration of enterococci in recreational water.},
  author={James W Messer and Alfred P. Dufour},
  journal={Applied and environmental microbiology},
  year={1998},
  volume={64 2},
  pages={678-80}
}
A two-step membrane filter (MF) method with mE medium, upon which the membrane must be incubated for 48 h and then transferred to a substrate medium to differentiate enterococci, is recommended by the U.S. Environmental Protection Agency to measure enterococci in fresh and marine recreational waters. The original mE medium was modified by reducing the triphenyltetrazolium chloride from 0.15 to 0.02 g/liter and adding 0.75 g of indoxyl beta-D-glucoside per liter. The new MF medium, mEI medium… CONTINUE READING