A preliminary in vivo trial of load transfer in mandibular implant-retained overdentures anchored in 2 different ways: allowing and counteracting free rotation.

@article{Menicucci2006API,
  title={A preliminary in vivo trial of load transfer in mandibular implant-retained overdentures anchored in 2 different ways: allowing and counteracting free rotation.},
  author={Giulio Menicucci and Paola Ceruti and Eva Barabino and Antonio Screti and Cristina Bignardi and Giulio Preti},
  journal={The International journal of prosthodontics},
  year={2006},
  volume={19 6},
  pages={
          574-6
        }
}
This in vivo pilot methodologic study used 3 patients to investigate load transfer in mandibular implant-retained overdentures anchored in 2 different ways: allowing (gap condition) and counteracting (contact condition) free rotation. Load cells and strain-gauged abutments were used to evaluate occlusal load, load transmitted to the nonworking-side mucosa, and stress on the working-side abutment, in both contact and gap conditions. The occlusal load was reduced and load was shifted from… CONTINUE READING