A novel quantitative method for determining the biodistribution of radiolabeled xenobiotics using whole-body cryosectioning and autoradioluminography.

Abstract

A novel method is described for quantitative whole-body autoradioluminography using [14C]-radioactive standards prepared from rat red blood cells. MicroComputer Imaging Device model 2 (MCID) and ImageQuant (IQ) imaging systems were evaluated for imaging performance and autoradioluminography quantitation. Weighted linear regression analysis resulted in… (More)