A new magnetic resonance electrical impedance tomography (MREIT) algorithm: the RSM-MREIT algorithm with applications to estimation of human head conductivity.

@article{Gao2006ANM,
  title={A new magnetic resonance electrical impedance tomography (MREIT) algorithm: the RSM-MREIT algorithm with applications to estimation of human head conductivity.},
  author={Nuo Gao and Shanan Zhu and Bin He},
  journal={Physics in medicine and biology},
  year={2006},
  volume={51 12},
  pages={3067-83}
}
We have developed a new magnetic resonance electrical impedance tomography (MREIT) algorithm, the RSM-MREIT algorithm, for noninvasive imaging of the electrical conductivity distribution using only one component of magnetic flux density. The proposed RSM-MREIT algorithm uses the response surface methodology (RSM) algorithm for optimizing the conductivity distribution through minimizing the errors between the measured and calculated magnetic flux densities. A series of computer simulations has… CONTINUE READING
Highly Cited
This paper has 136 citations. REVIEW CITATIONS

Topics

Statistics

02040'07'08'09'10'11'12'13'14'15'16'17'18
Citations per Year

136 Citations

Semantic Scholar estimates that this publication has 136 citations based on the available data.