A model of the cost-effectiveness of intensity-modulated radiotherapy in comparison with three-dimensional conformal radiotherapy for the treatment of localised prostate cancer.

@article{Hummel2012AMO,
  title={A model of the cost-effectiveness of intensity-modulated radiotherapy in comparison with three-dimensional conformal radiotherapy for the treatment of localised prostate cancer.},
  author={Silvia R Hummel and Matthew D Stevenson and E L Simpson and John N. Staffurth},
  journal={Clinical oncology (Royal College of Radiologists (Great Britain))},
  year={2012},
  volume={24 10},
  pages={e159-67}
}
AIMS To determine the cost-effectiveness of intensity-modulated radiotherapy (IMRT) compared with three-dimensional conformal radiotherapy (3DCRT) for men with localised prostate cancer from a UK National Health Service perspective. MATERIALS AND METHODS A discrete event simulation model was developed to simulate the progress of patients through advancing disease states until death from prostate cancer or other causes. Clinical effectiveness data for IMRT and 3DCRT were derived from a… CONTINUE READING
Recent Discussions