A mechanical comparison between conventional and modified angular plates for proximal humeral fractures.

Abstract

The objective of this study is to present a modified angular blade plate for fixing 2-part and even 3-part fractures of the proximal humerus, as well as the results of the comparative mechanical test between the conventional angular blade plate and this new modified plate. The plates were tested in flexion and rotational trials in a wooden model that… (More)
DOI: 10.1016/j.jse.2008.02.003