A detection scheme for paraquat poisoning: validation and a five-year experience in Australia.

@article{Taylor2001ADS,
  title={A detection scheme for paraquat poisoning: validation and a five-year experience in Australia.},
  author={P. J. Taylor and Paul Salm and Peter Ian Pillans},
  journal={Journal of analytical toxicology},
  year={2001},
  volume={25 6},
  pages={
          456-60
        }
}
We report the validation of a quantitative method for paraquat in plasma and urine using high-performance liquid chromatography (HPLC) with ultraviolet detection (260 nm). Furthermore, we illustrate the use of this method in the clinic (over five years), in conjunction with a qualitative urine paraquat screen. Urine or plasma sample (1 mL) preparation was performed in duplicate using C18 solid-phase extraction. Chromatographic separation was achieved on a Zorbax RX-Silica column (250 x 4.6-mm i… CONTINUE READING

From This Paper

Figures, tables, and topics from this paper.

References

Publications referenced by this paper.
SHOWING 1-10 OF 29 REFERENCES

Simultaneous determination of paraquat and diquat in human tissues by high-performance liquid chromatography

  • T. Nagata, K. Kudo, K. Kimura, T. Imamura
  • J. Chromatogr
  • 1993
2 Excerpts

, S . Ameno , T . Kiriu , T . Shinohara , and K . Sogo . A rapid , simultaneous determination of paraquat and diquat in serum and urine using second - derivative spectroscopy

  • S. Mathialagan Smith
  • J . Anal ToxicoL
  • 1992

Similar Papers