A comparison of volume conductor and source geometry effects on body surface and epicardial potentials.

@article{Rudy1980ACO,
  title={A comparison of volume conductor and source geometry effects on body surface and epicardial potentials.},
  author={Yoram Rudy and Robert Plonsey},
  journal={Circulation research},
  year={1980},
  volume={46 2},
  pages={283-91}
}
Using an analytical mathematical model, we studied and contrasted the effects of variations in geometry and volume conductor properties of the torso on epicardial and body surface potentials. The model consists of a spherical heart (blood cavity bounded by a spherical muscle shell that includes a double layer source, and pericardium) eccentrically placed in a spherical torso flung region bounded by muscle and fat layers). The effects of the following parameters on body surface and epicardial… CONTINUE READING

Citations

Publications citing this paper.
Showing 1-10 of 31 extracted citations

Ranking the Influence of Tissue Conductivities on Forward-Calculated ECGs

IEEE Transactions on Biomedical Engineering • 2010
View 8 Excerpts
Highly Influenced

The forward problem of electrocardiography revisited.

Circulation. Arrhythmia and electrophysiology • 2015

Multi-component heart reconstruction from volumetric imaging

Symposium on Solid and Physical Modeling • 2008
View 3 Excerpts

References

Publications referenced by this paper.
Showing 1-10 of 21 references

Similar Papers