A W: B4C multilayer phase retarder for broadband polarization analysis of soft x-ray radiation.

@article{Macdonald2008AWB,
  title={A W: B4C multilayer phase retarder for broadband polarization analysis of soft x-ray radiation.},
  author={Michael Macdonald and Franz Schaefers and Ralph Pohl and I. B. Poole and Andreas Gaupp and F. M. Quinn},
  journal={The Review of scientific instruments},
  year={2008},
  volume={79 2 Pt 1},
  pages={
          025108
        }
}
A W: B4C multilayer phase retarder has been designed and characterized which shows a nearly constant phase retardance between 640 and 850 eV photon energies when operated near the Bragg condition. This freestanding transmission multilayer was used successfully to determine, for the first time, the full polarization vector at soft x-ray energies above 600 eV, which was not possible before due to the lack of suitable optical elements. Thus, quantitative polarimetry is now possible at the 2p edges… 

Figures and Tables from this paper

A single W/B4C transmission multilayer for polarization analysis of soft x-rays up to 1keV.
A transmission W/B(4)C multilayer has been designed and characterized which shows significant phase retardation up to a photon energy of 1 keV, when operated near the Bragg condition. This allows,
Measurement of the polarization for soft x-ray magnetic circular dichroism at the BSRF beamline 4B7B
Three ultra-short-period W/B_4C multilayers (1.244 nm, 1.235 nm and 1.034 nm) have been fabricated and used for polarization measurement at the 4B7B Beamline at the Beijing Synchrotron Radiation
Development and performance of a versatile soft X-ray polarimeter
With modern undulators generating light of an arbitrary polarization state, experiments exploiting this feature in the soft X-ray region are becoming increasingly widespread. Circularly polarized
High-precision soft x-ray polarimeter at Diamond Light Source.
TLDR
The development and performance of a high-precision polarimeter for the polarization analysis in the soft x-ray region is presented and complete polarization analysis of the APPLE II undulator at 712 eV has been performed.
Multilayer based soft-x-ray polarimeter at MAX IV Laboratory.
A high precision five rotation-axes polarimeter using transmission multilayers as polarizers and reflection multilayers as analyzers has been designed and manufactured. To cover the extreme
Development and performance test of a soft x-ray polarimeter and ellipsometer for complete polarization analysis.
TLDR
It is for the first time shown that the degree of linear polarization of monochromatized light from the BL-11 is approximately 87% at 92 eV since the beamline has been constructed.
Freestanding multilayer films for application as phase retarders and spectral purity filters in the soft x-ray and EUV ranges
A technique for fabrication of freestanding multilayers which are able to be used as optical elements in the soft X-ray and EUV ranges is reported. Two types of transmission mode elements have been
Spectral tailoring of nanoscale EUV and soft x-ray multilayer optics
Extreme ultraviolet and soft X-ray (XUV) multilayer optics have experienced significant development over the past few years, particularly on controlling the spectral characteristics of light for
EUV polarimetry for thin film and surface characterization and EUV phase retarder reflector development.
TLDR
An EUV spectroscopic ellipsometer facility for polarimetry in the 90-160 nm spectral range is presented and a single layer aluminum mirror to be used as a quarter wave retarder has been fully characterized by deriving the optical and structural properties from the amplitude component and phase difference δ measurements.
...
1
2
3
...

References

SHOWING 1-10 OF 46 REFERENCES
Phase-retardation and full-polarization analysis of soft-x-ray synchrotron radiation close to the carbon K edge by use of a multilayer transmission filter.
TLDR
A multilayer transmission filter with 100 periods of Cr/C is produced to achieve a significant phase retardation while maintaining good transmission for photon energies just below the carbon K edge, allowing, for the first time, a complete and unambiguous polarization analysis of soft-x-ray synchrotron radiation with primary standards.
Soft x‐ray (97‐eV) phase retardation using transmission multilayers
Phase retardation as a function of incidence angle of 97‐eV soft x rays from a laser plasma source on transmission through a free‐standing molybdenum/silicon multilayer was measured using a
Soft-x-ray polarimeter with multilayer optics: complete analysis of the polarization state of light.
TLDR
With these newly developed optical elements the complete polarization analysis of soft-x-ray synchrotron radiation can be extended to the water-window range from 300 to 600 eV.
Cr /sc multilayers for the soft-x-ray range.
TLDR
The performance theoretically expected with respect to reflection/transmission and energy resolution has been confirmed experimentally and a value of 7% for the normal-incidence peak reflectance was measured as well as a pronounced minimum in transmission for certain incidence angles and energies below the respective absorption edges, indicating significant phase-shifting effects.
Design of an X-ray Phase-Plate Analyzer to Measure the Circular Polarization Rate of a Helical Undulator Source.
TLDR
A quarter-wave plate made of a ca 16 mum-thick silicon single-crystal was used at energies as low as 2.8 keV to convert circularly polarized photons into linearly polarized photons, enabling the characterization of the circular polarization rate of the radiation emitted by one of the ESRF helical undulators, Helios-I.
Measurement of the polarization of extreme ultraviolet synchrotron radiation with a reflecting polarimeter.
TLDR
The polarization of extreme uv light provided by a normal incidence monochromator used with synchrotron radiation from the 6-GeV electron synch rotatedron DESY has been measured and is in excellent agreement with the calculated polarization of the light incident upon the monochromaator grating.
...
1
2
3
4
5
...