A Noniterative Optimized Algorithm for Shunt Active Power Filter Under Distorted and Unbalanced Supply Voltages

@article{Kanjiya2013ANO,
  title={A Noniterative Optimized Algorithm for Shunt Active Power Filter Under Distorted and Unbalanced Supply Voltages},
  author={P. Kanjiya and V. Khadkikar and H. Zeineldin},
  journal={IEEE Transactions on Industrial Electronics},
  year={2013},
  volume={60},
  pages={5376-5390}
}
  • P. Kanjiya, V. Khadkikar, H. Zeineldin
  • Published 2013
  • Computer Science, Mathematics
  • IEEE Transactions on Industrial Electronics
  • In this paper, a single-step noniterative optimized algorithm for a three-phase four-wire shunt active power filter under distorted and unbalanced supply conditions is proposed. The main objective of the proposed algorithm is to optimally determine the conductance factors to maximize the supply-side power factor subject to predefined source current total harmonic distortion (THD) limits and average power balance constraint. Unlike previous methods, the proposed algorithm is simple and fast as… CONTINUE READING
    Optimal Control of Shunt Active Power Filter to Meet IEEE Std. 519 Current Harmonic Constraints Under Nonideal Supply Condition
    • 55
    • Open Access
    An Improved Hybrid DSTATCOM Topology to Compensate Reactive and Nonlinear Loads
    • 84
    • Open Access
    An Improved Current Controller for Grid Connected Voltage Source Converter in Microgrid Applications
    • 21
    • Highly Influenced
    Application of Artificial Neural Networks for Shunt Active Power Filter Control
    • 88

    References

    Publications referenced by this paper.
    SHOWING 1-10 OF 24 REFERENCES
    A review of active filters for power quality improvement
    • 2,294
    • Open Access
    Comparison of Control Strategies for Shunt Active Power Filters in Three-Phase Four-Wire Systems
    • 590
    • Open Access
    A DSP Based Optimal Algorithm for Shunt Active Filter Under Nonsinusoidal Supply and Unbalanced Load Conditions
    • 121
    • Highly Influential
    • Open Access
    An Optimization-Based Algorithm for Shunt Active Filter Under Distorted Supply Voltages
    • 67
    • Highly Influential
    • Open Access
    An optimal and flexible control strategy for active filtering and power factor correction under non-sinusoidal line voltages
    • 98
    • Highly Influential
    A new approach for optimal shunt active power filter control considering alternative performance indices
    • 55
    Optimisation-based strategy for shunt active power filter control under non-ideal supply voltages
    • 44