316L Stainless Steel Manufactured by Selective Laser Melting and Its Biocompatibility with or without Hydroxyapatite Coating

@inproceedings{Luo2018316LSS,
  title={316L Stainless Steel Manufactured by Selective Laser Melting and Its Biocompatibility with or without Hydroxyapatite Coating},
  author={Jiapeng Luo and Xiao Jia and Suhang Yang and Peng Zhou and Yongjiang Huang and Jianfei Sun and Ming Yan},
  year={2018}
}
To fabricate metallic 316L/HA (hydroxyapatite) materials which meet the requirements of an implant’s mechanical properties and bioactivity for its function as human bone replacement, selective laser melting (SLM) has been employed in this study to prepare a 316L stainless steel matrix, which was subsequently covered with a hydroxyapatite (HA) coating using the sol-gel method. High density (98.9%) as-printed parts were prepared using a laser power of 230 W and a scanning speed of 800 mm/s… CONTINUE READING

Similar Papers

References

Publications referenced by this paper.