[Transfusional hemolytic reactions of an alloantibody not determinable by standard methods of compatibility].

@article{Talarico1986TransfusionalHR,
  title={[Transfusional hemolytic reactions of an alloantibody not determinable by standard methods of compatibility].},
  author={Ernest F. Talarico and Maria Sassi},
  journal={Acta bio-medica de L'Ateneo parmense : organo della Societa di medicina e scienze naturali di Parma},
  year={1986},
  volume={57 3-4},
  pages={
          73-7
        }
}
Anti-e is rare as allontiboby, relatively frequent as autoantibody. A case of immediate haemolytic transfusion reaction (IHTR) in a patient with a high-titer alloantiboby of this specificity, not revealed in cross-match, is described.