[Iris suture fixation of posterior-chamber elastic intraocular lens in ligament apparatus laxity].

Abstract

An original MIOL-23 multifocal elastic intraocular lens (IOL) was used to operate 5 eyes with acquired lens dislocation and traumatic cataract. By making self-sealing tunnel incision, ILO was implanted into the capsular sac and sutured to the iris. MIOL-23 implantation caused an increase in mean visual acuity. The IOL took up a correct position. Elastic IOL… (More)