[Frequency-specific analysis of the hVOR Prior of Cochlear Implant Operation].


Dizziness is one of the most common postoperative complications after a cochlear-implant (CI) surgery. With our prospective, matched-paired controlled study, we could demonstrate that patients with distinctive sensorineural hearing loss--even without any complaints of dizziness--already have a reduced horizontal vestibular-ocular-reflex (hVOR). Compared to… (More)
DOI: 10.1055/s-0034-1384529