[Evaluation of setup error and adequate setup margins in patients with prostate cancer treated by IMRT and fixed in the prone position using a set of immobilization devices].

@article{Takakura2006EvaluationOS,
  title={[Evaluation of setup error and adequate setup margins in patients with prostate cancer treated by IMRT and fixed in the prone position using a set of immobilization devices].},
  author={Toru Takakura and Manabu Nakata and Shinsuke Yano and Takashi Okada and Takahiro Fujimoto and Kana Matsubara and Takashi Mizowaki and Kenji Takayama and Yoshinori Norihisa},
  journal={Nihon Hoshasen Gijutsu Gakkai zasshi},
  year={2006},
  volume={62 1},
  pages={130-5}
}
PURPOSE Positional reproducibility in patients with prostate cancer fixed in the prone position with a set of immobilization devices for external-beam intensity-modulated radiation therapy (IMRT) was evaluated. In addition, the adequacy of our positional error reduction strategy and current planning target volume (PTV) margins was also evaluated. RESULTS Systematic error was corrected by the positional correction that we executed at the first stage of irradiation. The setup margin that we had… CONTINUE READING

From This Paper

Figures, tables, results, connections, and topics extracted from this paper.
0 Extracted Citations
5 Extracted References
Similar Papers

Referenced Papers

Publications referenced by this paper.
Showing 1-5 of 5 references

Treatment Planning , Dose Delivery and Outcome Of IMRT For Localized Prostate Cancer , A Practical GuideTo INTENSITYMODULATED RADIATIONTHERAPY

  • CM Burman, MJ Zelefsky, A LeibelSteven
  • Med Phys
  • 2003

Clinical experience with intensity modulated radiation therapy(IMRT)in prostate cancer

  • Z Fuks, L Happersett
  • Radiother Oncol
  • 2000

The probability of correct target dosage : dosepopulation histograms for deriving treatment margins in radiotherapy

  • M vanHerk, P Remeijer, C Rasch
  • Int J Radiat Oncol Biol Phys
  • 2000