Zhenghua Song

Learn More
  • Z Song, X Zhou
  • Spectrochimica acta. Part A, Molecular and…
  • 2001
A novel chemiluminescence (CL) sensor for folic acid combined flow-injection (FI) technology was presented in this paper. The analytical reagents involved in the CL reaction, including luminol and hexacyanoferrate(III), were both immobilized on an anion-exchange column in FI system. The CL signal produced by the reaction between luminol and(More)
A sensitive chemiluminescence method based on a luminol-myoglobin system is proposed for the determination of melamine in milk products. It was found that the mixed solutions of melamine and myoglobin could react to form a complex on line, which could greatly inhibit the chemiluminescence intensity generated from the reaction between luminol and myoglobin.(More)
A new flow injection method for the determination of folic acid is described. A fast oxidation reaction occurred when folic acid was mixed with potassium ferricyanide generating ferrocyanide which then inhibited the chemiluminescent reaction of ferricyanide and luminol in alkaline medium. The decrease of chemiluminescence intensity was correlated with the(More)
A selective and sensitive as well as rapid chemiluminescence (CL) flow sensor for the determination of analgin is described. The analytical reagents involved in chemiluminescence reaction, luminol and periodate, were both immobilized on an anion-exchange column. The CL signals produced by the reaction between luminol and periodate, which were eluted from(More)
It was first found that the intrinsic fluorescence of lysozyme at 340 nm can be quenched by cephalosporin analogues through the static quenching and non-radiative energy transferring procedure. In the acetate buffer solution with pH 7.0 and 298 K, the quenching fluorescence intensity was in a good linearity over the concentration of drugs in the range of(More)
A sensitive flow injection chemiluminescence method, based on the inhibitory effect of chlorogenic acid on the reaction between luminol and dissolved oxygen, was presented for the determination of chlorogenic acid. It was found that the decrease of chemiluminescence intensity was linear with the logarithm of chlorogenic acid concentration over the range(More)
An interesting inhibitory effect of rutin on the chemiluminescence (CL) reaction between luminol and periodate was reported, and this effect was used for the determination of rutin in medicine and human urine. The CL reagents, luminol and periodate, were both immobilized on an anion-exchange column. The CL signal produced by the reaction between luminol and(More)
The luminol-bovine serum albumin chemiluminescence system was proposed for the first time. It was found that the hydrophilic luminol bound to the hydrophilic domain at Trp(134) of BSA with accelerating the electrons transferring rate of excited 3-aminophthalate, which led to the enhancement CL intensity of luminol at 425 nm. The increment of(More)
A sensitive flow injection-chemiluminescence (FI-CL) method for the determination of isocarbophos (ICP) residue on tangerines and oranges was proposed. It was found that the CL intensity from luminol-albumin CL reaction could be obviously quenched in the presence of ICP and the decrease in CL intensity was proportional to the logarithm of ICP concentrations(More)
A novel analytical procedure based on chemiluminescence (CL) detection was described for the determination of lysozyme at ng ml(-1) level by using controlled-reagent-release technology in a flow injection system. The analytical reagents involved in the CL reaction, including luminol and periodate, were both immobilized on the anion-exchange resins in the(More)