The most frequent initial rhythm in out-of-hospital witnessed cardiac arrest is ventricular fibrillation (VF) and electrical defibrillation is still the only effective therapy for the termination of this life-threatening cardiac arrhythmia. Even though earlier defibrillation is greatly emphasized during cardiopulmonary resuscitation (CPR), unnecessary or(More)
Various filtering strategies have been adopted and investigated to suppress the cardiopulmonary resuscitation (CPR) artifact. In this article, two types of artifact removal methods are reviewed: one is the method that removes CPR artifact using only ECG signals, and the other is the method with additional reference signals, such as acceleration, compression(More)
OBJECTIVE Quantitative ventricular fibrillation (VF) waveform analysis is a potentially powerful tool to optimize defibrillation. However, whether combining VF features with additional attributes that related to the previous shock could enhance the prediction performance for subsequent shocks is still uncertain. METHODS A total of 528 defibrillation(More)
Early cardiopulmonary resuscitation together with early defibrillation is a key point in the chain of survival for cardiac arrest. Optimizing the timing of defibrillation by predicting the possibility of successful electric shock can guide treatments between defibrillation and cardiopulmonary resuscitation and improve the rate of restoration of spontaneous(More)
INTRODUCTION Quantitative electrocardiographic (ECG) waveform analysis provides a noninvasive reflection of the metabolic milieu of the myocardium during resuscitation and is a potentially useful tool to optimize the defibrillation strategy. However, whether combining multiple ECG features can improve the capability of defibrillation outcome prediction in(More)
To overcome the problems of current electrocardiogram (ECG) tele-monitoring devices used for daily life, according to information fusion thought and by means of wearable technology, we developed a new type of wearable ECG monitor with the capability of physical activity recognition in this paper. The ECG monitor synchronously detected electrocardiogram(More)
BACKGROUND Biphasic waveforms are superior to monophasic waveforms for the termination of ventricular fibrillation (VF). However, whether triphasic waveforms are more effective than biphasic ones is still controversial. In the present study, we investigated the effects of second and third phase duration of triphasic rectangle waveform on defibrillation(More)
BACKGROUND Quantitative analysis of ventricular fibrillation (VF), such as amplitude spectral area (AMSA), predicts shock outcomes. However, there is no uniform definition of shock/cardiopulmonary resuscitation (CPR) success in out-of-hospital cardiac arrest (OHCA). The objective of this study is to investigate post-shock rhythm variations and the impact of(More)
Cardiopulmonary resuscitation (CPR) must be interrupted for reliable rhythm analysis in current automatic external defibrillators because of artifacts produced by chest compressions. However, interruptions in CPR adversely affect the restoration of spontaneous circulation and survival. Suppressing CPR artifacts by digital signal processing techniques is a(More)
The present study describes a rapid and sensitive HPLC method for the quantification of huperzine A (HupA) in Huperzia crispata (Huperziaceae). The sample extraction and preparation involved a simple, time-saving, single-solvent extraction, with each sample being analyzed within 12 min. The mobile phase was ammonium acetate (0.1 M, pH 6.0)--methanol (64 +(More)