Learn More
This paper focuses on an optimal quadrature error correction method for the dual-mass MEMS gyroscope, in order to reduce the long term bias drift. It is known that the coupling stiffness and demodulation error are important elements causing bias drift. The coupling stiffness in dual-mass structures is analyzed. The experiment proves that the left and right(More)
BACKGROUND/AIMS Hashimoto's encephalopathy is considered as a treatable dementia, but it is often misdiagnosed. We investigated cognitive impairment and the MRI pathology of Hashimoto's encephalopathy patients. METHODS The study comprised eight patients with Hashimoto's encephalopathy, 16 patients with mild Alzheimer's disease and 24 healthy subjects. A(More)
This paper describes the design and implementation of a radiosonde which can measure the meteorological temperature, humidity, pressure, and other atmospheric data. The system is composed of a CPU, microwave module, temperature sensor, pressure sensor and humidity sensor array. In order to effectively solve the humidity sensor condensation problem due to(More)
The main part of the magnetic fluxgate sensor is the magnetic core, the hysteresis characteristic of which affects the performance of the sensor. When the fluxgate sensors are modelled for design purposes, an accurate model of hysteresis characteristic of the cores is necessary to achieve good agreement between modelled and experimental data. The(More)
Aiming at the relationships of the high altitude meteorological parameters, such as longitude, latitude, atmospheric pressure, temperature and humidity, the methods of least squares fitting test data and error analysis by MATLAB are proposed in this paper. Temperature, humidity and air pressure change curve equations are established at the different(More)
Resonant Tunneling Diodes (RTD) and High Electron Mobility Transistor (HEMT) based on GaAs, as the piezoresistive sensing element, exhibit extremely high sensitivity in the MEMS sensors based on GaAs. To further expand their applications to the fields of MEMS sensors based on Si, we have studied the optimization of the GaAs epitaxy layers on Si wafers.(More)
The different noise components in a dual-mass micro-electromechanical system (MEMS) gyroscope structure is analyzed in this paper, including mechanical-thermal noise (MTN), electronic-thermal noise (ETN), flicker noise (FN) and Coriolis signal in-phase noise (IPN). The structure equivalent electronic model is established, and an improved white Gaussian(More)
BACKGROUND To explore the use of hepcidin as a marker of impaired renal function in a rat model for chronic allograft nephropathy (CAN). MATERIAL AND METHODS Twenty-four models were developed and 20 models were included in this study, using Fisher (F344) rats (donors) and Lewis rats (recipients). Renal function tests were performed preoperatively and(More)