A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions (ABSORB II): an interim 1-year
BACKGROUND Despite rapid dissemination of an everolimus-eluting bioresorbable scaffold for treatment for coronary artery disease, no data from comparisons with its metallic stent counterpart areExpand
Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II): a 3 year, randomised, controlled,
BACKGROUND No medium-term data are available on the random comparison between everolimus-eluting bioresorbable vascular scaffolds and everolimus-eluting metallic stents. The study aims to demonstrateExpand
Anatomical and clinical characteristics to guide decision making between coronary artery bypass surgery and percutaneous coronary intervention for individual patients: development and validation of
BACKGROUND The anatomical SYNTAX score is advocated in European and US guidelines as an instrument to help clinicians decide the optimum revascularisation method in patients with complex coronaryExpand
Evaluation of the second generation of a bioresorbable everolimus-eluting vascular scaffold for the treatment of de novo coronary artery stenosis: 12-month clinical and imaging outcomes.
OBJECTIVES The aim of this study was to demonstrate that the prevention of early scaffold area shrinkage of the ABSORB BVS (Rev.1.1, Abbott Vascular, Santa Clara, California) was sustained and notExpand
A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods
BACKGROUND Drug-eluting metallic coronary stents predispose to late stent thrombosis, prevent late lumen vessel enlargement, hinder surgical revascularisation, and impair imaging with multislice CT.Expand
Early and persistent intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve.
OBJECTIVES In this retrospective study, we examined the incidence of post-procedural conduction abnormalities and the need for pacing in patients undergoing percutaneous implantation of the aorticExpand
Identification of putative palytoxin as the cause of clupeotoxism.
In 1994 in Madagascar a woman died after eating a sardine, Herklotsichthys quadrimaculatus. Two heads removed, respectively, from a toxic and a nontoxic fish before cooking were retrieved, keptExpand
A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): a prospective open-label trial
BACKGROUND A fully bioabsorbable drug-eluting coronary stent that scaffolds the vessel wall when needed and then disappears once the acute recoil and constrictive remodelling processes have subsidedExpand
Value of the SYNTAX score in patients treated by primary percutaneous coronary intervention for acute ST-elevation myocardial infarction: The MI SYNTAXscore study.
AIMS The aims of this study were to evaluate the SYNTAX score (SXscore) calculated at 2 stages during a primary percutaneous intervention (PPCI), that is, SXscore I (diagnostic) and SXscore IIExpand
A randomized trial evaluating everolimus-eluting Absorb bioresorbable scaffolds vs. everolimus-eluting metallic stents in patients with coronary artery disease: ABSORB Japan.
AIMS Theoretically, bioresorbable vascular scaffolds (BVSs) may provide superior long-term results compared with permanent metallic drug-eluting stents (DESs). However, whether BVSs are as safe andExpand
...