Presently, 2 to 4 days elapse between sampling at infection suspicion and result of microbial diagnostics. This delay for the identification of pathogens causes quite often a late and/or inappropriate initiation of therapy for patients suffering from infections. Bad outcome and high hospitalization costs are the consequences of these currently existing(More)
Volatile metabolites of Aspergillus fumigatus and Candida species can be detected by gas chromatography/mass spectrometry (GC/MS). A multi-capillary column - ion mobility spectrometer (MCC-IMS) was used in this study to assess volatile organic compounds (VOCs) in the headspace above A. fumigatus and the four Candida species Candida albicans, Candida(More)
Multicapillary column (MCC) ion mobility spectrometers (IMS) are increasingly in demand for medical diagnosis, biological applications and process control. In a MCC-IMS, volatile compounds are differentiated by specific retention time and ion mobility when rapid preseparation techniques are applied, e.g. for the analysis of complex and humid samples.(More)
BACKGROUND We aimed to measure propofol concentrations in exhaled air with an ion mobility spectrometer coupled to a multicapillary column for pre-separation (MCC-IMS). In addition, we aimed to compare the values of these measurements with serum propofol concentrations, as determined by gas chromatography-mass spectrometry (GC-MS). METHODS Thirteen(More)
Ion mobility spectrometry is known to be a fast and sensitive technique for the detection of trace substances, and it is increasingly in demand not only for protection against explosives and chemical warfare agents, but also for new applications in medical diagnosis or process control. Generally, a gas phase sample is ionized by help of ultraviolet light,(More)
BACKGROUND Although "uremic fetor" has long been felt to be diagnostic of renal failure, the compounds exhaled in uremia remain largely unknown so far. The present work investigates whether breath analysis by ion mobility spectrometry can be used for the identification of volatile organic compounds retained in uremia. METHODS Breath analysis was performed(More)
For the comprehensive simulation of ion trajectories including reactive collisions at elevated pressure conditions, a chemical reaction simulation (RS) extension to the popular SIMION software package was developed, which is based on the Monte Carlo statistical approach. The RS extension is of particular interest to SIMION users who wish to simulate ion(More)
Exhaled breath can provide comprehensive information about the metabolic state of the subject. Breath analysis carried out during animal experiments promises to increase the information obtained from a particular experiment significantly. This feasibility study should demonstrate the potential of ion mobility spectrometry for animal breath analysis, even(More)
Ion mobility spectrometry is a fast and sensitive analytical method for the detection of gas phase analytes in the ppb(v)-ppt(v) range under ambient conditions (pressure and temperature). Ion mobility spectrometers coupled with rapid pre-separation like multi-capillary columns (MCC/IMS) are suitable for the selective characterization of complex and humid(More)
Emissions from surfaces (from furniture, wall paintings or floor coverings for instance) significantly influence indoor air quality and therefore the wellbeing or even the health of the occupants. Together with metabolites from mold they are responsible for the well-known "sick building syndrome". Therefore, it is in the interest of the manufacturer as well(More)