William A. Osborn

  • Citations Per Year
Learn More
The oxidation behaviors of LiH under a high purity argon atmosphere, an argon atmosphere with some O2 and H2O impurities, and ambient air at both room and high temperatures, are investigated using a variety of analytical instruments including X-ray diffractometry, thermogravimetry, mass spectrometry, scanning electron microscopy, and specific surface area(More)
The unique properties of metallic nanoclusters are attractive for numerous commercial and industrial applications but are generally less stable than nanocrystals. Thus, developing methodologies for stabilizing nanoclusters and retaining their enhanced functionality is of great interest. We report the assembly of PPh3-protected Au9 clusters from a(More)
We present a new methodology to accurately measure strain magnitudes from 3D nanodevices using Electron Backscatter Diffraction (EBSD). Because the dimensions of features on these devices are smaller than the interaction volume for backscattered electrons, EBSD patterns from 3D nanodevices will frequently be the superposition of patterns from multiple(More)
To better assess risks associated with nano-enabled products including multiwalled carbon nanotubes (MWCNT) within polymer matrices, it is important to understand how MWCNT are dispersed throughout the composite. The current study presents a method which employs imaging X-ray photoelectron spectroscopy (XPS) to chemically detect spatially segregated MWCNT(More)
Patterned SiGe thin film structures, heteroepitaxially deposited on Si substrates, are investigated as potential reference standards to establish the accuracy of high resolution electron backscattered diffraction (HR-EBSD) strain measurement methods. The proposed standards incorporate thin films of tetragonally distorted epitaxial Si₁-xGex adjacent to(More)
Mode correction factors (MCFs) represent a significant adjustment to the spring constant values measured using the thermal cantilever calibration method. Usually, the ideal factor of 0.971 for a tipless rectangular cantilever is used, which adjusts the value by 3% for the first flexural mode. An experimental method for determining MCFs has been developed(More)
Calibration of the flexural spring constant for atomic force microscope (AFM) colloid probe cantilevers provides significant challenges. The presence of a large attached spherical added mass complicates many of the more common calibration techniques such as reference cantilever, Sader, and added mass. Even the most promising option, AFM thermal calibration,(More)
The long-term cyclic durability of nano-engineered solid-state hydrogen storage systems is investigated using LiNH2+LiH as a model system. Through 60 hydriding and dehydriding cycles over the course of more than 200 h, a small decrease in the kinetics of the dehydrogenation reaction leads to a 10% reduction in the amount of hydrogen liberated during a 2.5 h(More)
Laboratory notebooks have been a staple of scientific research for centuries for organizing and documenting ideas and experiments. Modern laboratories are increasingly reliant on electronic data collection and analysis, so it seems inevitable that the digital revolution should come to the ordinary laboratory notebook. The most important aspect of this(More)
  • 1