Learn More
Fifteen cases of vitreous floaters with serious psychological reactions have been collected. By using a direct ophthalmoscope, causal vitreous opacities were detected. The opacities were photodisrupted with neodymium YAG laser, using energy levels of 5 to 7.1 mJ and total energy 71 to 742.0 mJ. Symptoms completely disappeared immediately after treatment in(More)
The bacterial findings of 73 maxillary sinuses in 48 patients with chronic maxillary sinusitis, together with 7 non-inflamed sinuses, are reported. Employing an intraoperative technique and simultaneous collection of 3 different types of specimens in the present investigation made possible comparison of their bacterial characteristics. The results indicated(More)
Software Testing is a challenging activity for many software engineering projects and it is one of the five main technical activity areas of the software engineering lifecycle that still poses substantial challenges. Testing software requires enough resources and budget to complete it successfully. But most of the organizations face the challenges to(More)
The unconventional superconductivity in the newly discovered iron-based superconductors is intimately related to its multiband/multiorbital nature. Here we report the comprehensive orbital characters of the low-energy three-dimensional electronic structure in BaFe 1.85 Co 0.15 As 2 by studying the polarization and photon-energy dependence of angle-resolved(More)
PURPOSE The reporting of the occurrence of central serous chorioretinopathy in a patient with congenital optic pits. METHODS A 31-year-old man complained of blurred vision in the right eye for 1 week. He had a visual acuity of 20/25 in the right eye. He underwent ophthalmoscopy and fluorescein angiography. RESULTS Ophthalmoscopy revealed serous(More)
There has been growing interest in searching for exotic self-conjugate, charge-neutral low-energy fermionic quasi-particles, known as Majorana fermions (MFs) in solid state systems. Their signatures have been proposed and potentially observed at edges of topological superconcuctors with non-trivial topological invariant in the bulk electronic band(More)
The potential acuity meter (PAM) was designed to evaluate visual acuity in 22 eyes that required secondary capsulotomies. The PAM prediction was within one line in 13 eyes (59%) and within two lines in 17 eyes (77%) and had an 18% rate of falsely bad prediction (more than two lines) and 5% rate of falsely good prediction for YAG capsulotomy. In aphakic(More)
  • 1