Vijay K Rana

Learn More
A tracking system has been developed to provide real-time feedback of skin dose and dose rate during interventional fluoroscopic procedures. The dose tracking system (DTS) calculates the radiation dose rate to the patient's skin using the exposure technique parameters and exposure geometry obtained from the x-ray imaging system digital network (Toshiba(More)
We have developed a dose-tracking system (DTS) to manage the risk of deterministic skin effects to the patient during fluoroscopic image-guided interventional cardiac procedures. The DTS calculates the radiation dose to the patient's skin in real-time by acquiring exposure parameters and imaging-system geometry from the digital bus on a Toshiba C-arm unit(More)
The skin dose tracking system (DTS) that we developed provides a color-coded illustration of the cumulative skin dose distribution on a 3D graphic of the patient during fluoroscopic procedures for immediate feedback to the interventionist. To improve the accuracy of dose calculation, we now have incorporated two additional important corrections (1) for the(More)
PURPOSE Neurovascular interventional procedures using biplane fluoroscopic imaging systems can lead to increased risk of radiation-induced skin injuries. The authors developed a biplane dose tracking system (Biplane-DTS) to calculate the cumulative skin dose distribution from the frontal and lateral x-ray tubes and display it in real-time as a color-coded(More)
We have developed a dose-tracking system (DTS) that calculates the radiation dose to the patient's skin in real-time by acquiring exposure parameters and imaging-system-geometry from the digital bus on a Toshiba Infinix C-arm unit. The cumulative dose values are then displayed as a color map on an OpenGL-based 3D graphic of the patient for immediate(More)
The aim of this work is to develop a method to calculate lens dose for fluoroscopically-guided neuro-interventional procedures and for CBCT scans of the head. EGSnrc Monte Carlo software is used to determine the dose to the lens of the eye for the projection geometry and exposure parameters used in these procedures. This information is provided by a digital(More)
PURPOSE To develop a library of graphic human models that closely match patients undergoing interventional fluoroscopic procedures in order to obtain an accurate estimate of their skin dose. METHODS A dose tracking system (DTS) has been developed that calculates the dose to the patient's skin in real time during fluoroscopic procedures based on a(More)
We have developed a dose-tracking system (DTS) that provides a real-time display of the skin-dose distribution on a 3D patient graphic during fluoroscopic procedures. Radiation dose to individual points on the skin is calculated using exposure and geometry parameters from the digital bus on a Toshiba C-arm unit. To accurately define the distribution of(More)
PURPOSE To develop pediatric graphic models for a real-time skin dose-tracking system (DTS) and to verify the accuracy of dose and dose-rate determination with these models for cardiac projections. METHODS A system has been developed to track skin dose during fluoroscopic interventional procedures and to provide a graphic representation of the cumulative(More)
A biplane dose-tracking system (Biplane-DTS) that provides a real-time display of the skin-dose distribution on a 3D-patient graphic during neuro-interventional fluoroscopic procedures was developed. Biplane-DTS calculates patient skin dose using geometry and exposure information for the two gantries of the imaging system acquired from the digital system(More)