Tyler Heinl

Learn More
Radio tomographic imaging (RTI) has recently been proposed for tracking object location via radio waves without requiring the objects to transmit or receive radio signals. The position is extracted by inferring which voxels are obstructing the various radio links in a dense wireless sensor network. This paper derives an analytic expression for the image(More)
Different systems of self-cutting screws are tested by a measuring instrument to test the torsional strain. Modern methods of measuring techniques are applied to get results of the torsional force and the torque by screwing into the bones. To get a self-cutting screw system several methods of biomechanical properties must be applied. A variety of quality(More)
Three years of clinical use and testing provided clear support to the advantages of the self-tapping titanium splithole screws. Although having rather flat heads these screws afford a fast grip with the screw driver blade. In addition to this, the pin offers good axial guidance and adhesion of the screw. The cylindrical design of the screw equator improves(More)