Using a questionnaire, we surveyed 2,500 facilities in Japan to clarify medical accidents concerning the magnetic resonance device and its environment. Data derived from 1,319 valid responses (52.8%), allowed us to analyze the situation of (or the reason for) the occurrence of the accidents and their environmental factors. Five hundred and nine facilities(More)
OBJECTIVE The aim of the study was to investigate the causes of apparent diffusion coefficient (ADC) measurement errors and to determine the optimal scanning parameters that are independent of the field strength and vendors of the magnetic resonance (MR) system. MATERIALS AND METHODS Brain MR images of 10 healthy volunteers were scanned using 6 MR(More)
When measuring the signal-to-noise ratio (SNR) of an image the used parallel magnetic resonance imaging, it was confirmed that there was a problem in the application of past SNR measurement. With the method of measuring the noise from the background signal, SNR with parallel imaging was higher than that without parallel imaging. In the subtraction method(More)
The apparent diffusion coefficient (ADC) values are calculated by using signal intensity in diffusion-weighted images (DWIs) with two or more different b-value. Therefore, the signal to noise ratio (SNR) of DWI with higher b-value may have a big influence on the measured ADC value. We examined the influence of the imaging parameters on the calculated ADC(More)
Parallel magnetic resonance imaging (MRI) with arrays of receiver coils such as those of sensitivity encoding (SENSE) are being widely used. However, conventional methods of image signal-to-noise ratio (SNR) determination cannot be used for parallel MRI, and a novel method has been reported in JSRT. However, this method of SNR determination is for phantom(More)
In many clinical imaging procedures using arrays of multiple receiver coils, a uniform sensitivity process is performed using the sensitivity distribution from the body coil. This causes the noise to be uneven, and background noise cannot be used when measuring the signal-to-noise ratio (SNR). The SNR of clinical images with sensitivity correction using(More)
PURPOSE To quantitatively investigate in vitro the effects of flip angle (FA), receiver bandwidth (BW), echo time (TE), and magnetic field strength (FS) on image noise and artifacts induced by stent-assisted coiling on contrast-enhanced MR angiography (CE-MRA) images, as a first step towards optimization of imaging parameters. METHODS A phantom simulating(More)
Diffusion weighted imaging (DWI) is now widely used in magnetic resonance (MR) imaging of the head and body. Moreover, the Apparent diffusion coefficient (ADC) value is often used for the differential diagnosis of the tumor. However, the effect of the surroundings on the ADC value has not been reported. In this study, we used the phantom completely sealed(More)
The definitional equation of the distortion of echo planar imaging(EPI)was examined. We compared measured values with calculated values by using the definitional equation of the chemical shift of the EPI method that first composed the diffusion-weighted image, and examined the possibility of applying it to the distortion. The results showed that the(More)