BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent.(More)
AIMS Patients with ST-segment elevation myocardial infarction (STEMI) feature thrombus-rich lesions with large necrotic core, which are usually associated with delayed arterial healing and impaired stent-related outcomes. The use of bioresorbable vascular scaffolds (Absorb) has the potential to overcome these limitations owing to restoration of native(More)
INTRODUCTION Reduced left ventricular function in patients with severe symptomatic valvular aortic stenosis is associated with impaired clinical outcome in patients undergoing surgical aortic valve replacement (SAVR). Transcatheter Aortic Valve Implantation (TAVI) has been shown non-inferior to SAVR in high-risk patients with respect to mortality and may(More)
OBJECTIVES This study sought to assess the impact of permanent pacemaker (PPM) implantation on clinical outcomes among patients undergoing transfemoral transcatheter aortic valve implantation (TAVI). BACKGROUND TAVI is associated with atrioventricular-conduction abnormalities requiring PPM implantation in up to 40% among patients treated with(More)
BACKGROUND Previous analyses reported age- and gender-related differences in the provision of cardiac care. The objective of the study was to compare circadian disparities in the delivery of primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI) according to the patient's age and gender. METHODS We investigated patients(More)
The filter-bank system implemented in hearing aids has to fulfill various constraints such as low latency and high stop-band attenuation, usually at the cost of low frequency resolution. In the context of frequency-domain noise-reduction algorithms, insufficient frequency resolution may lead to annoying residual noise artifacts since the spectral harmonics(More)
INTRODUCTION Rheumatic heart disease (RHD) remains a major contributor to morbidity and mortality in developing countries. The reported prevalence rates of RHD are highly variable and mainly attributable to differences in the sensitivity of either clinical screening to detect advanced heart disease or echocardiographic evaluation where disease is diagnosed(More)
BACKGROUND Dual antiplatelet therapy (DAPT) with aspirin plus a P2Y12 inhibitor prevents ischaemic events after coronary stenting, but increases bleeding. Guidelines support weighting bleeding risk before the selection of treatment duration, but no standardised tool exists for this purpose. METHODS A total of 14 963 patients treated with DAPT after(More)
BACKGROUND The safety and effectiveness of the fully repositionable LOTUS valve system as compared with the balloon-expandable Edwards SAPIEN 3 prosthesis for the treatment of aortic stenosis has not been evaluated to date. METHODS AND RESULTS All patients undergoing transcatheter aortic valve implantation with the Edwards SAPIEN 3 or the LOTUS valve(More)