BACKGROUND Current guidelines do not recommend implantable cardioverter-defibrillator (ICD) implantation in patients with a life expectancy of <1 year. Better methods are needed for identifying patients at high risk for early mortality despite ICD therapy. OBJECTIVE To develop and validate a risk prediction score to identify patients at high risk for(More)
BACKGROUND Sprint Fidelis (Fidelis) implantable cardioverter-defibrillator leads are prone to fractures that have caused adverse events, primarily inappropriate shocks, and a few reported deaths. More than 100 000 patients have Fidelis leads. No independent multicenter long-term performance information exists for this lead, and single-center studies suggest(More)
INTRODUCTION The Medtronic Sprint Fidelis implantable cardioverter defibrillator (ICD) lead was "recalled" in October 2007 after 268,000 implants worldwide due to increased failure risk. Manufacturer suggested monitoring has not been shown effective at preventing adverse events. Only limited data exist regarding clinical predictors of Fidelis lead fracture.(More)
OBJECTIVES This study sought to compare all-cause mortality in patients with Fidelis leads (Medtronic, Minneapolis, Minnesota) to those with a nonadvisory lead. BACKGROUND Although Fidelis leads are prone to fracture, and rare deaths due to lead failure have been reported, it is unclear whether the presence of a Fidelis lead is associated with increased(More)
Mass spectrometry-based screening can be applied to a wide range of targets, including those intractable targets that use substrates such as lipids, fatty acids, phospholipids, steroids, prostaglandins, and other compounds not generally amenable to conventional screening techniques. The major limitation to this approach is throughput, making HTS via mass(More)
PURPOSE To determine steady state milrinone concentrations in patients with stage D heart failure (HF) with and without renal dysfunction METHODS We retrospectively identified patients with stage D HF at a single medical center on continuous milrinonein fusion at the time of plasma collection for entry into a research registry database. Milrinone was(More)
The Medtronic Riata implantable cardioverter–defibrillator (ICD) lead is a 7-Fr ICD lead shown to have a propensity for cardiac perforation. This report details two pediatric cases of cardiac perforation in patients with a Riata ICD lead. Analysis regarding the effect of ICD implantation techniques on cardiac perforation specific to pediatric patients is(More)
Background—Sprint Fidelis (Fidelis) implantable cardioverter-defibrillator leads are prone to fractures that have caused adverse events, primarily inappropriate shocks, and a few reported deaths. More than 100 000 patients have Fidelis leads. No independent multicenter long-term performance information exists for this lead, and single-center studies suggest(More)