Thibault Carteret

Learn More
OBJECTIVES Acoustic radiation force impulse (ARFI) technology represents an innovative method for the quantification of tissue elasticity. The aims of this study were to evaluate elasticity by ARFI in both liver tumors and background liver tissue and to compare ARFI measurements with histologic data in liver tumors and background liver. METHODS(More)
Studies of percutaneous cryotherapy in the treatment of benign or malignant soft tissue tumours are rare and mainly involve small populations. Nevertheless, results show cryotherapy's potential in terms of local control of tumours, analgesic efficacy, reduced intra- and postoperative complications, and reduction in the length of convalescence after the(More)
The present article describes two cases of bronchopleural fistula (BPF) occurring after radiofrequency ablation of lung tumors. Both procedures were carried out using expandable multitined electrodes, with no coagulation of the needle track. After both ablations, ground-glass opacities encompassed the nodules and abutted the visceral pleura. The first(More)
MR thermometry offers the possibility to precisely guide high-intensity focused ultrasound (HIFU) for the noninvasive treatment of kidney and liver tumours. The objectives of this study were to demonstrate therapy guidance by motion-compensated, rapid and volumetric MR temperature monitoring and to evaluate the feasibility of MR-guided HIFU ablation in(More)
UNLABELLED An increased use of peripherally inserted central catheters (PICC) in French hospitals has been observed in recent years. We report complications having occurred following the placement of PICC in a teaching hospital. PATIENTS AND METHODS A prospective study was made for 7 months, between October 2010 and April 2011, including all patients(More)
To prospectively evaluate a novel implant, Y-STRUT® (Hyprevention, Pessac, France), designed to provide prophylactic reinforcement of the proximal femur in metastatic patients. Ten patients presenting lytic lesions of the proximal femur were to be treated. The device consisted of two components implanted in the proximal femur, combined with bone cement.(More)
BACKGROUND We studied Y-STRUT® (Hyprevention, France), a new percutaneous internal fixation device, in combination with bone cementoplasty to prevent hip fracture. METHODS Between February 2013 and February 2015, a total of 16 femoral necks in 4 osteoporotic and 12 oncologic patients have been considered for prophylactic consolidation in this prospective(More)