Design methodologies of planar duplexer and triplexer consisting of bandpass filters (BPFs) using different tapped resonators are described. Firstly, we propose a planar duplexer consisting of BPFs using a tapped half-wavelength resonator and a tapped quarter-wavelength resonator. The duplexer is designed based on a classical filter design method with a(More)
This paper proposes a new method for line fault analysis of ungrounded distribution systems. The fault condition of a line fault is integrated into the nodal admittance matrix of the faulted line to be modeled. The zero-impedance branch is merged into adjacent impedance branches to be taken into account, and one of its terminal buses with zero(More)
This paper proposes a decoupled three-phase load flow analysis method for unbalanced distribution systems. The power flows are solved through nodal current injection mismatch equations written in rectangular coordinates. The voltage changes resulting from nodal current injection mismatches and nodal admittance matrix have been decoupled into one(More)
– This paper proposes a hybrid three-phase load flow method for ungrounded distribution systems. Based on topology connectivity analysis, the system is partitioned into a main-line system and multiple tap systems. A Newton method with constant admittance matrix is used to solve the mainline system, such that zero impedance branches are merged into adjacent(More)
This paper proposes a fast and robust load flow method for balanced power distribution systems with distributed generation sources. The method formulates generation sources. The method formulates the power flow equations in PQ decoupled form with polar coordinates. Second-order terms are included in the active power mismatch iteration, and resistances are(More)
This paper proposes a new method for determining single-phase-to-ground fault locations of ungrounded distribution systems based on the measurements collected from the feeder breakers and intelligent switches during the fault. The method first narrows down the possible faulted area into a specific feeder section based on the reactive power factors of(More)
This paper proposes a generalized admittance based method for fault location analysis of distribution systems. Based on the measurements collected from the feeder breakers and intelligent switches during a fault, the fault type and faulted feeder section are first determined by examining the over-voltages and over-currents on the breakers/switches. The load(More)
This paper proposes a generalized admittance based method for fault location analysis of distribution systems. Based on the measurements collected from the feeder breakers and intelligent switches during a fault, the fault type and faulted feeder section are first determined by examining the over-voltages and over-currents on the breakers/switches. The load(More)
This paper proposes a hybrid current profile based fault location algorithm for double-line-to-ground (DLG) faults in a distribution system. The method uses both short-circuit fault current profile (average of fault currents recorded for the faulted phases) and during-fault load current profile (corresponding to the un-faulted phase) to estimate an accurate(More)
This paper proposes a hybrid decoupled power flow method for balanced power distribution systems with distributed generation sources. The method formulates the power flow equations in active power and reactive power decoupled form with polar coordinates. Second-order terms are included in the active power mismatch iteration, and constant Jacobian and(More)