• Publications
  • Influence
Diffusion-Weighted Magnetic Resonance Imaging for Diagnosing Malignant Pulmonary Nodules/Masses: Comparison with Positron Emission Tomography
Introduction: Recent developments of diffusion-weighted magnetic resonance imaging (DWI) make it possible to image malignant tumors to provide tissue contrast based on difference in the diffusion ofExpand
  • 172
  • 11
Diffusion-weighted magnetic resonance imaging can be used in place of positron emission tomography for N staging of non-small cell lung cancer with fewer false-positive results.
OBJECTIVE One of the deficiencies of positron emission tomography for N staging in lung cancer is a false-positive result caused by concurrent lymphadenitis. Recently, diffusion-weighted magneticExpand
  • 135
  • 9
  • PDF
Is diffusion-weighted magnetic resonance imaging superior to positron emission tomography with fludeoxyglucose F 18 in imaging non-small cell lung cancer?
OBJECTIVE This retrospective analysis examined whether diffusion-weighted magnetic resonance imaging might be as useful as positron emission tomography with fludeoxyglucose F 18 for (1)Expand
  • 63
  • 6
A severe outbreak of haemorrhagic colitis and haemolytic uraemic syndrome associated withEscherichia coli 0157: H7 in Japan
In 1990, an outbreak ofEscherichia coli 0157: H7 infection occurred in 174 children in a nursery school in Saitama, Japan. The organism was isolated from tap water supplied from the well in theExpand
  • 68
  • 6
A Multicenter, Open-Label Clinical Study of Micafungin (FK463) in the Treatment of Deep-seated Mycosis in Japan
The efficacy and safety of micafungin (FK463), which is a new lipopeptide antifungal agent of the echinocandin class and is active against both Aspergillus and Candida species, were investigated inExpand
  • 141
  • 5
  • PDF
Geothermometry of spinel lherzolites
Three methods of geothermometry, currently used for spinel lherzolites, are refined based on new experiments on subsolidus phase equilibria of olivine, pyroxenes and spinel in CaO-MgO-Al2O3-SiO2 andExpand
  • 74
  • 5
Differential diagnosis of ground-glass opacity nodules: CT number analysis by three-dimensional computerized quantification.
OBJECTIVES To differentiate among atypical adenomatous hyperplasia (AAH), bronchioloalveolar carcinoma (BAC), and adenocarcinoma showing ground-glass opacity (GGO) on CT scans, we conducted a studyExpand
  • 131
  • 4
Reinforcement learning for a biped robot based on a CPG-actor-critic method
TLDR
We propose in this article a reinforcement learning framework for a CPG controller, where the CPG-actor-critic is determined by a stochastic policy gradient. Expand
  • 111
  • 4
Laboratory Duplication of Phase Equilibria Observed in Natural Garnet Lherzolites
High pressure experiments have been carried out on two synthetic ultramafic compositions and also on natural mineral mixes at 30-40 kbar and 950-l,500°C. Olivine, orthopyroxene, clinopyroxene, andExpand
  • 123
  • 4
Petrology of peridotite and garnet clinopyroxenite of the Mt. Higasi-Akaisi mass, central Sikoku, Japan — Subsolidus relation of anhydrous phases
The mineralogy of anhydrous minerals of peridotite and garnet clinopyroxenite of the Mt. Higasi-Akaisi peridotite mass, Japan, is described. The subsolidus equilibria among garnet, clinopyroxene,Expand
  • 72
  • 4
...
1
2
3
4
5
...