The aim of this study was optimization of the radiation dose–image quality relationship for a digital scanning method of scoliosis radiography. The examination is performed as a digital multi-image translation scan that is reconstructed to a single image in a workstation. Entrance dose was recorded with thermoluminescent dosimeters placed dorsally on an(More)
In diagnostic radiology increasing attention has been focused on dose reduction while maintaining a clinically good image quality. With the use of digital detectors balancing dose vs image quality is done differently than in film-screen radiography, since dose and image brightness are uncoupled in digital imaging. In this study a new direct digital detector(More)
The aim of this study was to investigate the image quality for a flat-panel amorphous silicon detector at various radiation dose settings and to compare the results with storage phosphor plates and a screen-film system. A CDRAD 2.0 contrast-detail phantom was imaged with a flat-panel detector (Philips Medical Systems, Eindhoven, The Netherlands) at three(More)
In a previous part of this study, the fluoroscopy dose rate was reduced in a cardiac catheterization laboratory. The objectives of the present study were to evaluate the effects in a clinical population undergoing percutaneous coronary intervention (PCI) of the dose-reducing measures detailed previously. Kerma area-product (KAP) values were first recorded(More)
PURPOSE To evaluate the accuracy and reproducibility of a quantitative magnetic resonance (qMR) imaging method (QRAPMASTER) for simultaneous measurements of T1 and T2 relaxation times, and proton density (PD). MATERIALS AND METHODS Measurements of T1, T2, and PD with qMR were performed using phantoms with different relaxation times and concentrations of(More)
The objectives of this study were to quantify the impact of image post-processing parameters on the apparent renal stone size, and to quantify the intra- and inter-reader variability in renal stone size estimation. Fifty CT datasets including a renal or ureteral stone were included retrospectively during a prospective inclusion period. Each of the CT(More)
The workflow in radiology departments has changed dramatically with the transition to digital PACS, especially with the shift from tile mode to stack mode display of volumetric images. With the increasing number of images in routinely captured datasets, the standard user interface devices (UIDs) become inadequate. One basic approach to improve the(More)
The size estimation in CT images of an obstructing ureteral calculus is important for the clinical management of a patient presenting with renal colic. The objective of the present study was to develop a reader independent urinary calculus segmentation algorithm using well-known digital image processing steps and to validate the method against size(More)
The introduction of new flat-panel detector technology often forces us to accept too high dose levels as proposed by the manufacturers. We need a tool to compare the image quality of a new system with the accepted standard. The aim of this study was to obtain a comparable image quality for two systems—storage phosphor plates and a flat-panel system using(More)