Learn More
BACKGROUND Our institute started laparoscopic simulator training for medical students in 2006. During the training, we observed considerable interindividual differences in laparoscopic skills among those students. This study aimed to investigate the predictive factors that affect laparoscopic skill by assessing the students' training results data. METHODS(More)
PURPOSE The authors experimentally investigate the effect of direct energy conversion of x-rays via selfpowered Auger- and photocurrent, potentially suitable to practical radiation detection and dosimetry in medical applications. Experimental results are compared to computational predictions. The detector the authors consider is a thin-film multilayer(More)
We introduce a new x-ray radiation detector. The detector employs high-energy current (HEC) formed by secondary electrons consisting predominantly of photoelectrons and Auger electrons, to directly convert x-ray energy to detector signal without externally applied power and without amplification. The HEC detector is a multilayer structure composed of thin(More)
PURPOSE To fabricate organic photovoltaic (OPV) cells with nanometric active layers sensitive to ionizing radiation and measure their dosimetric characteristics in clinical x-ray beams in the diagnostic tube potential range of 60-150 kVp. METHODS Experiments were designed to optimize the detector's x-ray response and find the best parameter combination by(More)
This short paper is a work-in-progress report on an experimental comparison and evaluation of users' performance in four line-tracing tasks based on two shapes and performed with three input methods (mouse, stylus, and touch-input). The shapes' properties used in the study created the two classes of shapes: easy and hard to replicate. As expected these two(More)
In digital breast tomosynthesis and digital mammography, the x-ray beam filter material and thickness vary between systems. Replacing K-edge filters with Al was investigated with the intent to reduce exposure duration and to simplify system design. Tungsten target x-ray spectra were simulated with K-edge filters (50 µm Rh; 50 µm Ag) and Al filters of(More)
PURPOSE High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted(More)
PURPOSE To optimize the cesium iodide (CsI:Tl) scintillator thickness in a complimentary metal-oxide semiconductor (CMOS)-based detector for use in dedicated cone-beam breast CT. METHODS The imaging task considered was the detection of a microcalcification cluster comprising six 220µm diameter calcium carbonate spheres, arranged in the form of a regular(More)
PURPOSE To fabricate and test nanometric organic photovoltaic (OPV) cells made of various active-layer/electrode thicknesses and sizes; to determine the optimal material combinations and geometries suitable for dose measurements in clinical kilovoltage x-ray beams. METHODS The OPV consisted of P3HT:PCBM photoactive materials sandwiched between aluminum(More)