Steven J. Frank

Anita Mahajan2
Andrew K. Lee2
2Anita Mahajan
2Andrew K. Lee
Learn More
PURPOSE Intensity modulated proton therapy (IMPT) plans are normally generated utilizing multiple field optimization (MFO) techniques. Similar to photon based IMRT, MFO allows for the utilization of a simultaneous integrated boost in which multiple target volumes are treated to discrete doses simultaneously, potentially improving plan quality and(More)
PURPOSE To evaluate the outcomes of patients presenting with cancer at the base of the prostate after brachytherapy as monotherapy. MATERIAL AND METHODS We retrospectively reviewed the medical records of all patients who had undergone transperineal ultrasound-guided implantation with (125)I or (103)Pd seeds as monotherapy between March 1998 and December(More)
BACKGROUND We performed this study to assess outcomes of patients with oropharyngeal cancer treated with modern therapy approaches. METHODS Demographics, treatments and outcomes of patients diagnosed with Stage 3- 4B squamous carcinoma of the oropharynx, between 2000-2007 were tabulated and analyzed. RESULTS The cohort consisted of 1046 patients. The(More)
Normal tissue toxicity is an important consideration in the continued development of more effective external beam radiotherapy (EBRT) regimens for head and neck tumors. The ability to detect EBRT-induced changes in mandibular bone vascularity represents a crucial step in decreasing potential toxicity. To date, no imaging modality has been shown to detect(More)
Imaging metabolic dysfunction, a hallmark of solid tumors, usually requires radioactive tracers. Chemical exchange saturation transfer (CEST) imaging can potentially detect and visualize glucose uptake and metabolism, without the need for radioisotopes. Here, we tested the feasibility of using glucose CEST (glucoCEST) to image unlabeled glucose uptake in(More)
PURPOSE Computed tomography (CT)-based prostate post-implant dosimetry allows for definitive seed localization but is associated with high interobserver variation in prostate contouring. Currently, magnetic resonance imaging (MRI)-based post-implant dosimetry allows for accurate anatomical delineation but is limited due to inconsistent seed localization.(More)
An intensity-modulated proton therapy (IMPT) patient-specific quality assurance (PSQA) program based on measurement alone can be very time consuming due to the highly modulated dose distributions of IMPT fields. Incorporating independent dose calculation and treatment log file analysis could reduce the time required for measurements. In this article, we(More)
  • 1