Genetic distances were calculated among 37 inbred lines representing a wide range of related and unrelated elite Corn Belt germ plasm of maize (Zea Mays L.), using 257 probe restriction enzyme combinations. Genetic distances based on RFLP data were highly correlated with coefficients of parentage among pairs of lines. The RFLP-based distance had a higher(More)
Molecular imaging can potentially provide means for monitoring response to therapy in rheumatoid arthritis (RA) early in the course of disease [1].Quantitative measurements of RA disease activity made in the wrist by whole-body PET scanners, however, have inadequate accuracy because of limited spatial resolution [2]. A high-resolution PET/CT scanner for(More)
UNLABELLED We have constructed a dedicated breast PET/CT scanner capable of high-resolution functional and anatomic imaging. Here, we present an initial characterization of scanner performance during patient imaging. METHODS The system consisted of a lutetium oxyorthosilicate-based dual-planar head PET camera (crystal size, 3 x 3 x 20 mm) and 768-slice(More)
Kinetic parameters estimated from dynamic (18)F-fluorodeoxyglucose ((18)F-FDG) PET acquisitions have been used frequently to assess brain function in humans. Neglecting partial volume correction (PVC) for a dynamic series has been shown to produce significant bias in model estimates. Accurate PVC requires a space-variant model describing the reconstructed(More)
Improvements to current small animal PET scanners can be made by improving the sensitivity and the spatial resolution of the scanner. In the past, efforts have been made to minimize the crystal dimensions in the axial and transaxial directions to improve the spatial resolution and to increase the crystal length to improve the sensitivity of the scanner. We(More)
A dedicated breast PET/CT system has been constructed at our institution, with the goal of having increased spatial resolution and sensitivity compared to whole-body systems. The purpose of this work is to describe the design and the performance characteristics of the PET component of this device. Average spatial resolution of a line source in warm(More)
Modern positron emission tomography (PET) detectors are typically made from 2D modular arrays of scintillation crystals. Their characteristic flood field response (or flood histogram) must be segmented in order to correctly determine the crystal of annihilation photon interaction in the system. Crystal identification information thus generated is also(More)
A cross-sectional group study of the effects of aging on brain metabolism as measured with (18)F-FDG-PET was performed using several different partial volume correction (PVC) methods: no correction (NoPVC), Meltzer (MZ), Müller-Gärtner (MG), and the symmetric geometric transfer matrix (SGTM) using 99 subjects aged 65-87years from the Harvard Aging Brain(More)
BACKGROUND Simultaneous PET/MR imaging depends on MR-derived attenuation maps (mu-maps) for accurate attenuation correction of PET data. Currently, these maps are derived from gradient-echo-based MR sequences, which are sensitive to susceptibility changes. Iron oxide magnetic nanoparticles have been used in the measurement of blood volume, tumor(More)
Attenuation correction for PET-MR systems continues to be a challenging problem, particularly for body regions outside the head. The simultaneous acquisition of transmission scan based μ-maps and MR images on integrated PET-MR systems may significantly increase the performance of and offer validation for new MR-based μ-map algorithms. For the Biograph mMR(More)