Sornjarod Oonsiri

Learn More
OBJECTIVE The purposes of the present study were to determine the dose to medical staff in interventional radiology at different locations on the body measured by thermoluminescent dosimeter (TLD) and to relate the medical staff dose to patient dose measured by the dose-area product (DAP) meter. MATERIAL AND METHOD The present study covered 42 patients in(More)
DNA methylation and the repair of DNA double-strand breaks (DSBs) are important processes for maintaining genomic integrity. Although DSBs can be produced by numerous agents, they also occur spontaneously as endogenous DSBs (EDSBs). In this study, we evaluated the methylation status of EDSBs to determine if there is a connection between DNA methylation and(More)
BACKGROUND AND OBJECTIVE Three dimensional conformal radiation therapy (3D CRT) and intensity-modulated radiation therapy (IMRT) have been implemented at Department of Therapeutic Radiation and Oncology, King Chulalongkorn Memorial Hospital (KCMH) since July 2005. This is the first study in Thailand to evaluate the pattern of care and utilization of 3D CRT(More)
OBJECTIVE The authors present the result of a dosimetric comparison of inverse-planed intensity modulated, forward-planned intensity modulated, and conventional tangential technique in breast conserving radiotherapy. METHOD AND MATERIAL The breasts (Right side: Left side = 1:1), heart, and lungs of 28 patients were contoured on all the computed tomography(More)
OBJECTIVE This is the first report in Thailand to evaluate the efficacy of using intensity-modulated radiotherapy (IMRT) in the primary treatment of head-and-neck cancer. MATERIAL AND METHOD From July 2005 to March 2006, eighteen patients with head and neck cancer were treated with IMRT, fourteen of which were nasopharyngeal cancer. The median age at(More)
PURPOSE To measure the interfraction setup variation of patient undergoing intensity-modulated radiation therapy (IMRT) of head and neck cancer. The data was used to define adequate treatment CTV-to-PTV margin. MATERIALS AND METHODS During March to September 2006, data was collected from 9 head and neck cancer patients treated with dynamic IMRT using 6 MV(More)
PURPOSE To investigate the optimal sensitometric curves of extended dose range (EDR2) radiographic film in terms of depth, field size, dose range and processing conditions for dynamic intensity modulated radiation therapy (IMRT) dosimetry verification with 6 MV X-ray beams. MATERIALS AND METHODS A Varian Clinac 23 EX linear accelerator with 6 MV X-ray(More)
  • 1