BACKGROUND The metabolic phenotype that derives disproportionate energy via glycolysis in solid tumors, including glioma, leads to elevated lactate labeling in metabolic imaging using hyperpolarized [1-(13)C]pyruvate. Although the pyruvate dehydrogenase (PDH)-mediated flux from pyruvate to acetyl coenzyme A can be indirectly measured through the detection(More)
Fast chemical shift imaging (CSI) techniques are advantageous in metabolic imaging of hyperpolarized compounds due to the limited duration of the signal amplification. At the same time, reducing the acquisition time in hyperpolarized imaging does not necessarily lead to the conventional penalty in signal-to-noise ratio that occurs in imaging at thermal(More)
Ultrashort echo time imaging with half RF pulse excitation is sensitive to eddy currents induced by the slice-select gradient that distorts the half pulse slice profile. This work demonstrates improvements in the half pulse profile by using spatial saturation on both sides of the imaged slice to suppress the out-of-slice magnetization. This effectively(More)
PURPOSE The use of unlabeled exchange-linked dissolution agents in hyperpolarized metabolic imaging was studied to examine pool size limits and saturation relative to the availability of NADH. METHODS Three-dimensional dynamic metabolic images were obtained, and compared following injection of a bolus of hyperpolarized [1-(13)C]pyruvate, prepared with and(More)
In addition to an increased lactate-to-pyruvate ratio, altered metabolism of a malignant glioma can be further characterized by its kinetics. Spatially resolved dynamic data of pyruvate and lactate from C6-implanted female Sprague-Dawley rat brain were acquired using a spiral chemical shift imaging sequence after a bolus injection of a hyperpolarized(More)
Ultrashort echo time imaging with half RF pulse excitation is challenging as eddy currents induced by the slice-select gradient distort the half pulse slice profile. This work presents two pulses with T(2)-dependent slice profiles that are less sensitive to eddy currents. The double half pulse improves the slice selectivity for long T(2) components, while(More)
Undersampled spiral CSI (spCSI) using a free induction decay (FID) acquisition allows sub-second metabolic imaging of hyperpolarized ¹³C. Phase correction of the FID acquisition can be difficult, especially with contributions from aliased out-of-phase peaks. This work extends the spCSI sequence by incorporating double spin echo radiofrequency (RF) pulses to(More)
PURPOSE In contrast to [1-(13) C]pyruvate, hyperpolarized [2-(13) C]pyruvate permits the ability to follow the (13) C label beyond flux through pyruvate dehydrogenase complex and investigate the incorporation of acetyl-coenzyme A into different metabolic pathways. However, chemical shift imaging (CSI) with [2-(13) C]pyruvate is challenging owing to the(More)
PURPOSE Commonly used anesthetic agents such as isoflurane are known to be potent cerebral vasodilators, with reported dose-dependent increase in cerebral blood flow and cerebral blood volume. Despite the widespread use of isoflurane in hyperpolarized (13)C preclinical research studies, a quantitative assessment of its effect on metabolic measurements is(More)
PURPOSE MRS of hyperpolarized [2-(13)C]pyruvate can be used to assess multiple metabolic pathways within mitochondria as the (13)C label is not lost with the conversion of pyruvate to acetyl-CoA. This study presents the first MR spectroscopic imaging of hyperpolarized [2-(13)C]pyruvate in glioma-bearing brain. METHODS Spiral chemical shift imaging with(More)