BACKGROUND Although inhaled nitric oxide (iNO) causes selective pulmonary vasodilation and improves oxygenation in newborn infants with persistent pulmonary hypertension, its effects are variable. We hypothesized (1) that the response to iNO therapy is dependent on the primary disease associated with persistent pulmonary hypertension of the newborn (PPHN)(More)
BACKGROUND The safety and efficacy of early, low-dose, prolonged therapy with inhaled nitric oxide in premature newborns with respiratory failure are uncertain. METHODS We performed a multicenter, randomized trial involving 793 newborns who were 34 weeks of gestational age or less and had respiratory failure requiring mechanical ventilation. Newborns were(More)
Expression of IL-10 is decreased in lungs of preterm infants. We determined the constitutive and lipopolysaccharide (LPS)-induced IL-10 synthesis by lung inflammatory cells from preterm and term infants and examined their relationship to gestational age and/or incidence of bronchopulmonary dysplasia (BPD). A total of 37 infants; preterm neonates at(More)
Objective:To describe the accuracy of noninvasive hemoglobin (Hb) obtained with pulse co-oximeter (SpHb) compared with total Hb (tHb) from laboratory co-oximeter in neonates.Study design:Neonates with birth weight (BW) <3000 g admitted to LAC+USC Medical Center neonatal intensive care unit were included. SpHb was recorded using Masimo Radical-7 and compared(More)
Extremely low birth weight infants with chronic lung disease (CLD) have frequent episodes of desaturation (hypoxemia). We quantified oxygenation and episodes of hypoxemia in 55 infants (birth weight < or = 1000 gm) with CLD in the supine versus prone position, for 1-hour time intervals. Oxygen saturation was measured with the Nellcor N-200 pulse oximeter(More)
The reliability of pulse oximetry in neonates receiving inotropic drugs because of hypotension and microcirculatory perfusion failure has not been well documented. Signal loss of the pulse oximeter in adult patients receiving dopamine infusions has been reported. To evaluate the relationship between pulse oximeter oxygen saturation (SaO2) and co-oximeter(More)
OBJECTIVE To determine the changes in pulmonary mechanics before and during early dexamethasone therapy, and to evaluate the effect of dexamethasone on the duration of mechanical ventilation in very low birth weight (VLBW) ventilator-dependent infants at risk for chronic lung disease (CLD). METHODS A prospective randomized trial was conducted. Forty-three(More)
BACKGROUND Varying effects of pancuronium on neonatal pulmonary mechanics have been documented, including a decrease in pulmonary compliance or no significant change in compliance; but measurements of respiratory mechanics or quantification of episodes of hypoxemia in preterm newborns receiving vecuronium (Norcuron, Bedford Labs, Bedford, OH, USA) have not(More)
BACKGROUND Administration of hydrocortisone and relatively high doses of dexamethasone increase blood pressure in volume- and pressor-resistant hypotensive preterm infants. However, little is known about the temporal relationship of dexamethasone administration and the improvement in blood pressure and the weaning of pressors/inotropes. Furthermore, there(More)