Siôn Glyn-Jones

Learn More
We report 17 patients (20 hips) in whom metal-on-metal resurfacing had been performed and who presented with various symptoms and a soft-tissue mass which we termed a pseudotumour. Each patient underwent plain radiography and in some, CT, MRI and ultrasonography were also performed. In addition, histological examination of available samples was undertaken.(More)
BACKGROUND Tissue necrosis and a macrophage and perivascular lymphocytic infiltrate are commonly seen in periprosthetic tissues around metal-on-metal hip resurfacing implants, including pseudotumors associated with these implants. The purpose of the present study was to correlate pathological changes in periprosthetic tissues with clinical findings and the(More)
The Birmingham hip resurfacing (BHR) arthroplasty is a metal-on-metal prosthesis for which no medium- or long-term results have been published. Despite this, it is increasing in popularity as an alternative to stemmed prostheses for younger patients. Since the fixation of the socket is conventional, the major concern is long-term failure of the femoral(More)
The creep and wear behaviour of highly cross-linked polyethylene and standard polyethylene liners were examined in a prospective, double-blind randomised, controlled trial using radiostereometric analysis. We randomised 54 patients to receive hip replacements with either highly cross-linked polyethylene or standard liners and determined the(More)
Despite the satisfactory short-term implant survivorship of metal-on-metal hip resurfacing arthroplasty, periprosthetic soft-tissue masses such as pseudotumours are being increasingly reported. Cytotoxic effects of cobalt or chromium have been suggested to play a role in its aetiology. The aim of this study was to investigate the effects of clinically(More)
It is unclear whether it is best to use high-viscosity or low-viscosity cement for fixation of total hip replacement (THR) femoral components. This study examines the influence of cement viscosity on the migration of the Exeter femoral component using roentgen stereophotogrammetric analysis (RSA). Simplex, CMW1 and CMW3 G cements were examined in a total of(More)
We have evaluated the difference in the migration patterns over two years of two cementless stems in a randomised, controlled trial using radiostereophotogrammetric analysis (RSA). The implants studied were the Furlong HAC stem, which has good long-term results and the Furlong Active stem, which is a modified version of the former designed to minimise(More)
Metal-on-metal hip resurfacing is commonly performed for osteoarthritis in young active patients. We have observed cystic or solid masses, which we have called inflammatory pseudotumours, arising around these devices. They may cause soft-tissue destruction with severe symptoms and a poor outcome after revision surgery. The aim of this study was to determine(More)
Treatment for osteoarthritis (OA) has traditionally focused on joint replacement for end-stage disease. An increasing number of surgical and pharmaceutical strategies for disease prevention have now been proposed. However, these require the ability to identify OA at a stage when it is potentially reversible, and detect small changes in cartilage structure(More)
BACKGROUND The use of highly cross-linked polyethylene is now commonplace in total hip arthroplasty. Hip simulator studies and short-term in vivo measurements have suggested that the wear rate of highly cross-linked polyethylene is significantly less than that of conventional ultra-high molecular weight polyethylene. However, long-term data to support its(More)