Shryamalie R Ruberu

We don’t have enough information about this author to calculate their statistics. If you think this is an error let us know.
Learn More
The receptor-binding assay (RBA) method for determining saxatoxin (STX) and its numerous analogues, which cause paralytic shellfish poisoning (PSP) in humans, was evaluated in a single laboratory study. Each step of the assay preparation procedure including the performance of the multi-detector TopCount® instrument was evaluated for its contribution to(More)
High-performance liquid chromatography (HPLC) methods for the determination of phenyl urea herbicides in water are described. The target compounds include chlortoluron, diuron, fluometuron, isoproturon, linuron, metobromuron, metoxuron, monuron, neburon, and siduron. Water was subjected to solid phase extraction (SPE) using either automated SPE with 47 mm(More)
Groundwater wells from across the State of California were sampled and analyzed for Pb and Po. The separation method involved Fe(OH)3 precipitation from a 5-L groundwater sample followed by electrodeposition of Po on a nickel disk. The resulting solution was passed through an ion-exchange resin column for the isolation of Pb. De-ionized water spiked at a(More)
One hundred and twelve groundwater wells sampled from all the major aquifers in California were analyzed for 224Ra, 226Ra, 228Ra, gross alpha, and uranium. The results showed that radium is found in relatively low concentration, 1.56 x 10(-2)-1.23 Bq L(-1) (0.42-33 pCi L(-1)) for 224Ra, 2.2 x 10(-3)-0.81 Bq L(-1) (0.06-22 pCi L(-1)) for 226Ra, and 8.5 x(More)
A receptor binding assay (RBA) for detection of paralytic shellfish poisoning (PSP) toxins was formatted for use in a high throughput detection system using microplate scintillation counting. The RBA technology was transferred from the National Ocean Service, which uses a Wallac TriLux 1450 MicroBeta microplate scintillation counter, to the California(More)
A liquid scintillation counting (LSC) method having several advantages over the gas proportional counting (GPC) U.S. Environmental Protection Agency (EPA) Method 900.0 for the detection of gross alpha activity in drinking water was evaluated in this study. The improved method described here involves the use of nitromethane as the quench agent for(More)
The receptor-binding assay (RBA) method for the detection of paralytic shellfish poisoning (PSP) toxins was evaluated for its overall performance in comparison with the mouse bioassay (MBA). An initial study to evaluate the effects of filtering shellfish extracts prior to running the RBA indicated no significant difference between filtered and unfiltered(More)
  • 1