PURPOSE Continuous flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which causes a decrease in pulse pressure and pulsatility in the arteries and allegedly may lead to late complications such as aortic insufficiency and gastrointestinal bleeding. The purpose of this study is to increase the arterial pulse pressure and(More)
Continuous flow left ventricular assist devices (CF-LVADs) reduce arterial pulsatility, which may cause long-term complications in the cardiovascular system. The aim of this study is to improve the pulsatility by driving a CF-LVAD at a varying speed, synchronous with the cardiac cycle in an ex-vivo experiment. A Micromed DeBakey pump was used as CF-LVAD.(More)
This study was made because of the difficulty of resuscitating Mycoplasma meleagridis from agar cultures received from the field. The type strain of Mm was found viable following culture at 37 degrees C for as long as 10 days and maintenance at room temperature for a further 14 days but only when few colonies were present in the original culture. It is(More)
Dilated cardiomyopathy is the most common type of the heart failure which can be characterized by impaired ventricular contractility. Mechanical circulatory support devices were introduced into practice for the heart failure patients to bridge the time between the decision to transplant and the actual transplantation which is not sufficient due to the state(More)
Continuous flow left ventricular devices (CF-LVADs) support the failing heart at a constant speed and alters the loads on the aortic valve. This may cause insufficiency in the aortic valve under long-term CF-LVAD support. The aim of this study is to assess the aortic valve function under varying speed CF-LVAD support. A Medtronic freestyle valve and a(More)
Mathematical modelling has been used to comprehend the pathology and the assessment of different treatment techniques such as heart failure and left ventricular assist device therapy in the cardiovascular field. In this study, an in-silico model of the heart is developed to understand the effects of idiopathic dilated cardiomyopathy (IDC) as a pathological(More)
Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling(More)
The aim of this study is to understand whether the phasic Continuous Flow Left Ventricular Assist Device (CF-LVAD) support would increase the arterial pulsatility. A Micromed DeBakey CF-LVAD was used to apply phasic support in an ex-vivo experimental platform. CF-LVAD was operated over a cardiac cycle by phase-shifting the pulsatile pump control with(More)
In this study numerical models for the cardiovascular system and an axial left ventricular assist device were developed and control studies have been done in the scope of a TUBITAK funded project entitled “Design, analysis, and prototype production of a miniature implantable rotary blood pump.” Diseased cardiovascular system model was obtained(More)